Motion-Corrected Distortion Reduction Around Metallic Implant Using Diffusion Tensor Imaging at 3T

Motivation: The presence of metallic implants results in severe geometric distortion, limiting the ability of performing quantitative DTI measurement near the hardware. Goal(s): Goal: develop an acquisition method to address metal artifact DTI on post-operative patients with metallic hardware. Approach: A custom-built pulse sequence based on the combination of the reduced-Field-Of-View strategy and multi-shot EPI is suggested. Results: : In-vivo and in-vitro results show that the proposed approach provides distortion-reduced and signal void at the level of the metal hardware compared to the standard method. Impact: The ability of collecting reduced metal-artifact DTI maps around the hardware enables establishing imaging biomarkers to assess injury evolution and thoroughly evaluate microstructure changes after surgery.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2445
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motion-Corrected Distortion Reduction Around Metallic Implant Using Diffusion Tensor Imaging at 3T

Laura Krisa, Mahdi Alizadeh, Choukri Mekkaoui, Devon Middleton et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Motion-Corrected Distortion Reduction Around Metallic Implant Using Diffusion Tensor Imaging at 3T

Laura Krisa, Mahdi Alizadeh, Choukri Mekkaoui, Devon Middleton, Feroze B. Mohamed, Slimane Tounekti, Berkin Bilgic̦, Adam Leibold
article en

Abstract

Motivation: The presence of metallic implants results in severe geometric distortion, limiting the ability of performing quantitative DTI measurement near the hardware. Goal(s): Goal: develop an acquisition method to address metal artifact DTI on post-operative patients with metallic hardware. Approach: A custom-built pulse sequence based on the combination of the reduced-Field-Of-View strategy and multi-shot EPI is suggested. Results: : In-vivo and in-vitro results show that the proposed approach provides distortion-reduced and signal void at the level of the metal hardware compared to the standard method. Impact: The ability of collecting reduced metal-artifact DTI maps around the hardware enables establishing imaging biomarkers to assess injury evolution and thoroughly evaluate microstructure changes after surgery.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies