Motion Detection in Neonatal MR Fingerprinting: Enhancing Reliability in T1 and T2 values

Motivation: Motion artifact of MR Fingerprinting (MRF) cannot be recognized visually, but it affects quantitative values severely. Goal(s): We aimed to assess the impact of motion in MRF and propose an objective motion-detection method. Approach: We utilized Spatiotemporal Residuals (STR) from MRF-acquired signals and compared them with motion assessments in neonatal clinical practice. Results: Our results revealed that motion significantly affects the accuracy of both T1 and T2 values. By applying an appropriate threshold to the standard deviation of STR, we achieved highly accurate motion detection equivalent to expert visual judgment, which leads to robust accuracy of quantitative values. Impact: Our method to detect motion from MRF signals enables an objective assessment of the presence or absence of motion in MRF data. Consequently, this method facilitates the evaluation of the reliability of quantitative MRF images in clinical settings.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2370
Primary Topic
Fetal and Pediatric Neurological Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motion Detection in Neonatal MR Fingerprinting: Enhancing Reliability in T1 and T2 values

Mathias Nittka, Daisuke Utsunomiya, Gregor Koerzdoerfer, Noriko Aida et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Fetal and Pediatric Neurological Disorders
article

Motion Detection in Neonatal MR Fingerprinting: Enhancing Reliability in T1 and T2 values

Mathias Nittka, Daisuke Utsunomiya, Gregor Koerzdoerfer, Noriko Aida, Katsutoshi Murata, Ayumi Kato
article en

Abstract

Motivation: Motion artifact of MR Fingerprinting (MRF) cannot be recognized visually, but it affects quantitative values severely. Goal(s): We aimed to assess the impact of motion in MRF and propose an objective motion-detection method. Approach: We utilized Spatiotemporal Residuals (STR) from MRF-acquired signals and compared them with motion assessments in neonatal clinical practice. Results: Our results revealed that motion significantly affects the accuracy of both T1 and T2 values. By applying an appropriate threshold to the standard deviation of STR, we achieved highly accurate motion detection equivalent to expert visual judgment, which leads to robust accuracy of quantitative values. Impact: Our method to detect motion from MRF signals enables an objective assessment of the presence or absence of motion in MRF data. Consequently, this method facilitates the evaluation of the reliability of quantitative MRF images in clinical settings.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 67%
Fetal and Pediatric Neurological Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.