Up to 24-channel receiver coil arrays for concurrent TMS-MRI imaging at 3T

Motivation: Concurrent TMS-fMRI lacks whole-brain coverage or has low SNR. Goal(s): Develop setups allowing for whole-brain TMS-fMRI with high spatiotemporal resolution and minimizing the interference between MRI and TMS during data collection and neuromodulation. Approach: Combinations of 8- and 16-channel arrays enabled whole-brain TMS-MRI with 16 or 24 channels. Results: Structural and functional images of high spatiotemporal resolution (1.5 mm with 2 s/volume or 5 mm with 0.1 s/volume) were demonstrated with an MRI-compatible TMS coil. Impact: We developed concurrent TMS-MRI setups with whole-brain coverage and high spatiotemporal resolution using combinations of 8- and 16-channel coil arrays. Images of high spatiotemporal resolution were demonstrated.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2722
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Up to 24-channel receiver coil arrays for concurrent TMS-MRI imaging at 3T

Fa‐Hsuan Lin, Hsin-Ju Lee
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Up to 24-channel receiver coil arrays for concurrent TMS-MRI imaging at 3T

Fa‐Hsuan Lin, Hsin-Ju Lee
article en

Abstract

Motivation: Concurrent TMS-fMRI lacks whole-brain coverage or has low SNR. Goal(s): Develop setups allowing for whole-brain TMS-fMRI with high spatiotemporal resolution and minimizing the interference between MRI and TMS during data collection and neuromodulation. Approach: Combinations of 8- and 16-channel arrays enabled whole-brain TMS-MRI with 16 or 24 channels. Results: Structural and functional images of high spatiotemporal resolution (1.5 mm with 2 s/volume or 5 mm with 0.1 s/volume) were demonstrated with an MRI-compatible TMS coil. Impact: We developed concurrent TMS-MRI setups with whole-brain coverage and high spatiotemporal resolution using combinations of 8- and 16-channel coil arrays. Images of high spatiotemporal resolution were demonstrated.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Up to 24-channel receiver coil arrays for concurrent TMS-MRI imaging at 3T — Fa‐Hsuan Lin, Hsin-Ju Lee · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS