Extrapolated-B1-corrected Variable Flip Angle T1 Mapping in Cortical Bone with a Phase-Sensitive Method

Motivation: Unintended heating of the skull and nearby soft tissue during transcranial MR-guided Focused Ultrasound surgery needs to be monitored. However, T1-based thermometry in cortical bone may be biased with variable flip angles. Goal(s): Our goal was to correct flip angles to improve the T1 mapping accuracy in cortical bone. Approach: In phantom and human studies, B1 maps of soft tissue were measured with a phase-sensitive method, extrapolating from which B1 maps of bone were generated and were used to correct flip angles for T1 mapping. Results: Improved accuracy and homogeneity of T1 maps were demonstrated as validation. Impact: Extrapolated-B1 correction with a phase-sensitive method should improve accuracy and homogeneity of T1 maps in cortical bone and is promising in monitoring unintended heating in the skull and nearby brain tissue during transcranial MR-guided Focused Ultrasound surgery.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2701
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extrapolated-B1-corrected Variable Flip Angle T1 Mapping in Cortical Bone with a Phase-Sensitive Method

Steven P. Allen, John P. Mugler, G. Wilson Miller, Yekaterina Gilbo et al.
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Extrapolated-B1-corrected Variable Flip Angle T1 Mapping in Cortical Bone with a Phase-Sensitive Method

Steven P. Allen, John P. Mugler, G. Wilson Miller, Yekaterina Gilbo, Helen Sporkin, Samuel W. Fielden, Craig H. Meyer, Sheng Chen
article en

Abstract

Motivation: Unintended heating of the skull and nearby soft tissue during transcranial MR-guided Focused Ultrasound surgery needs to be monitored. However, T1-based thermometry in cortical bone may be biased with variable flip angles. Goal(s): Our goal was to correct flip angles to improve the T1 mapping accuracy in cortical bone. Approach: In phantom and human studies, B1 maps of soft tissue were measured with a phase-sensitive method, extrapolating from which B1 maps of bone were generated and were used to correct flip angles for T1 mapping. Results: Improved accuracy and homogeneity of T1 maps were demonstrated as validation. Impact: Extrapolated-B1 correction with a phase-sensitive method should improve accuracy and homogeneity of T1 maps in cortical bone and is promising in monitoring unintended heating in the skull and nearby brain tissue during transcranial MR-guided Focused Ultrasound surgery.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.