Reconfigurable Open-End Winding Motor Drive Topology for Inverter Short-Circuit Fault Tolerance

Existing open-end winding drives (OWDs) require relatively complex fault detection and diagnosis algorithms to handle inverter short-circuit faults. In addition, the motor cannot continue to output power with the disconnected drive. Therefore, this article proposes a topology reconfiguration OWD (TR-OWD) with a protection circuit that can quickly isolate an inverter short-circuit fault and reconfigure the drive topology after the fault. The current flow of the protection circuit during the fault transient and the transient and resonant state model are revealed first. Subsequently, based on the step current or voltage signals generated by the faulty inverter, the topology reconfiguration and voltage vector switching of the TR-OWD are presented, maintaining the original operating state of the motor. Finally, the experimental results of the motor with no-load and load conditions are shown to validate the effectiveness of the proposed short-circuit fault-tolerant design of the OWDs. The experimental results also verify the theoretical analysis.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2024-11-26
DOI
https://doi.org/10.1109/tpel.2024.3506789
Citations
11
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
2.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconfigurable Open-End Winding Motor Drive Topology for Inverter Short-Circuit Fault Tolerance

Zhiping Dong, Rundong Huang, Bowen Zhang, Chunhua Liu
11 citations
IEEE Transactions on Power Electronics
Multilevel Inverters and Converters
2.30
article

Reconfigurable Open-End Winding Motor Drive Topology for Inverter Short-Circuit Fault Tolerance

Zhiping Dong, Rundong Huang, Bowen Zhang, Chunhua Liu
article en
11 citations

Abstract

Existing open-end winding drives (OWDs) require relatively complex fault detection and diagnosis algorithms to handle inverter short-circuit faults. In addition, the motor cannot continue to output power with the disconnected drive. Therefore, this article proposes a topology reconfiguration OWD (TR-OWD) with a protection circuit that can quickly isolate an inverter short-circuit fault and reconfigure the drive topology after the fault. The current flow of the protection circuit during the fault transient and the transient and resonant state model are revealed first. Subsequently, based on the step current or voltage signals generated by the faulty inverter, the topology reconfiguration and voltage vector switching of the TR-OWD are presented, maintaining the original operating state of the motor. Finally, the experimental results of the motor with no-load and load conditions are shown to validate the effectiveness of the proposed short-circuit fault-tolerant design of the OWDs. The experimental results also verify the theoretical analysis.

IEEE Transactions on Power ElectronicsVol. 40(3)
City University of Hong Kong (HK)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 11%
Multilevel Inverters and Converters
2.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reconfigurable Open-End Winding Motor Drive Topology for Inverter Short-Circuit Fault Tolerance — Zhiping Dong, Rundong Huang, et al. · IEEE Transactions on Power Electronics (2024) | TGRS Research Map | TGRS