A Metal–Insulator–Metal Humidity Sensor Using Albumin–WO<sub>3</sub> Composites for Enhanced Responses

The growing demand for precise healthcare monitoring has fueled advancements in humidity sensor technology, which is crucial for applications in meteorology, environmental monitoring, industrial control, agriculture, and biomedical devices. In the biomedical realm, humidity sensors play a vital role in point-of-care testing devices for detecting respiratory conditions, such as bronchitis, asthma, and pneumonia. This study presents a two-terminal metal–insulator–metal (MIM) device utilizing a composite of chicken egg albumin and tungsten trioxide (WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>) as the active hygroscopic film, with aluminum and copper as the bottom and top electrodes, respectively. Albumin, a biocompatible and hydrophilic protein, efficiently absorbs moisture, while WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> nanoparticles, known for their excellent electrical conductivity, enhance the device's sensitivity to humidity changes. Experimental results demonstrate that increasing the WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> content in the composite film from 0% to 50% significantly improves the sensor's performance. Specifically, the maximum current response to humidity increased up to 15 times for pure albumin, 17.3 times for the albumin–WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> (25%) nanocomposite, and 21 times for the albumin–WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> (50%) nanocomposite, as the relative humidity varied from 20% to 95%. This work highlights the potential of albumin–WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> composites for diverse applications in environmental monitoring, healthcare, and industrial processes.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2024-11-26
DOI
https://doi.org/10.1109/lsens.2024.3498605
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.58
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Metal–Insulator–Metal Humidity Sensor Using Albumin–WO3 Composites for Enhanced Responses

Riya Sadhukhan, Arnab Ghosh, S. Santra, D. K. Goswami et al.
2 citations
IEEE Sensors Letters
Analytical Chemistry and Sensors
0.58
article

A Metal–Insulator–Metal Humidity Sensor Using Albumin–WO3 Composites for Enhanced Responses

Riya Sadhukhan, Arnab Ghosh, S. Santra, D. K. Goswami, S. K. Giri, Abhirup Das
article en
2 citations

Abstract

The growing demand for precise healthcare monitoring has fueled advancements in humidity sensor technology, which is crucial for applications in meteorology, environmental monitoring, industrial control, agriculture, and biomedical devices. In the biomedical realm, humidity sensors play a vital role in point-of-care testing devices for detecting respiratory conditions, such as bronchitis, asthma, and pneumonia. This study presents a two-terminal metal–insulator–metal (MIM) device utilizing a composite of chicken egg albumin and tungsten trioxide (WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>) as the active hygroscopic film, with aluminum and copper as the bottom and top electrodes, respectively. Albumin, a biocompatible and hydrophilic protein, efficiently absorbs moisture, while WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> nanoparticles, known for their excellent electrical conductivity, enhance the device's sensitivity to humidity changes. Experimental results demonstrate that increasing the WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> content in the composite film from 0% to 50% significantly improves the sensor's performance. Specifically, the maximum current response to humidity increased up to 15 times for pure albumin, 17.3 times for the albumin–WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> (25%) nanocomposite, and 21 times for the albumin–WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> (50%) nanocomposite, as the relative humidity varied from 20% to 95%. This work highlights the potential of albumin–WO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> composites for diverse applications in environmental monitoring, healthcare, and industrial processes.

IEEE Sensors LettersVol. 9(1)
Indian Institute of Technology Kharagpur (IN), Bell (Canada) (CA)
Affordable and clean energy
Openalex Percentile: Top 35%
Analytical Chemistry and Sensors
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.