Rolling Load Fatigue Experiment on a Bridge Deck Reinforced with a New Design of GFRP Stay-In-Place Form

A full-scale deck slab (15,240 mm × 3,890 mm × 210 mm) supported by steel girders spaced at 3.05 m, including a 3,810 mm × 3,890 mm section incorporating a new design of glass fiber–reinforced polymer (GFRP) stay-in-place (SIP) structural form, is tested under 3M rolling load cycles. The SIP form comprises transverse GFRP I-beams spanning the steel girders and GFRP ribbed plates (planks) spanning the transverse GFRP I-beams and supported by their lower flanges. The design of the SIP form was governed by readily available pultruded sections such that they meet deflection limits under self-weight of fresh concrete and also provide reinforcement ratios comparable to, or exceeding, the Canadian Highway Bridge Design Code (CHBDC) requirements for GFRP rebar. This deck section is compared with another section designed according to CHBDC with top and bottom GFRP rebar meshes. The deck was tested using the 250 kN Rolling Load Simulator (ROLLS) at Queen’s University, Canada, which is equipped with two half-axles spaced at 1.2 m, each comprising nitrogen-inflated dual tires. After 3M cycles, the section with SIP structural form showed very similar performance to that of the GFRP rebar section with the stiffness reducing by 72% in both. Nearly 90% of stiffness reduction occurred in the first 0.4M cycles. The residual deflection of the SIP form section was only 60% of that of the rebar section at 3M cycles. Live load deflection ratio reached 3.4 at 3M cycles, almost identical to the rebar section. The span/800 deflection limit was reached at 0.8M cycles, compared with 1.1M cycles for the rebar section. The maximum tensile strain reached in the GFRP SIP form system after 3M cycles was only 11% of its ultimate value.

Authors

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2024-11-26
DOI
https://doi.org/10.1061/jccof2.cceng-4708
Citations
4
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rolling Load Fatigue Experiment on a Bridge Deck Reinforced with a New Design of GFRP Stay-In-Place Form

Amir Fam, Chongxi Gao
4 citations
Journal of Composites for Construction
Structural Behavior of Reinforced Concrete
1.06
article

Rolling Load Fatigue Experiment on a Bridge Deck Reinforced with a New Design of GFRP Stay-In-Place Form

Amir Fam, Chongxi Gao
article en
4 citations

Abstract

A full-scale deck slab (15,240 mm × 3,890 mm × 210 mm) supported by steel girders spaced at 3.05 m, including a 3,810 mm × 3,890 mm section incorporating a new design of glass fiber–reinforced polymer (GFRP) stay-in-place (SIP) structural form, is tested under 3M rolling load cycles. The SIP form comprises transverse GFRP I-beams spanning the steel girders and GFRP ribbed plates (planks) spanning the transverse GFRP I-beams and supported by their lower flanges. The design of the SIP form was governed by readily available pultruded sections such that they meet deflection limits under self-weight of fresh concrete and also provide reinforcement ratios comparable to, or exceeding, the Canadian Highway Bridge Design Code (CHBDC) requirements for GFRP rebar. This deck section is compared with another section designed according to CHBDC with top and bottom GFRP rebar meshes. The deck was tested using the 250 kN Rolling Load Simulator (ROLLS) at Queen’s University, Canada, which is equipped with two half-axles spaced at 1.2 m, each comprising nitrogen-inflated dual tires. After 3M cycles, the section with SIP structural form showed very similar performance to that of the GFRP rebar section with the stiffness reducing by 72% in both. Nearly 90% of stiffness reduction occurred in the first 0.4M cycles. The residual deflection of the SIP form section was only 60% of that of the rebar section at 3M cycles. Live load deflection ratio reached 3.4 at 3M cycles, almost identical to the rebar section. The span/800 deflection limit was reached at 0.8M cycles, compared with 1.1M cycles for the rebar section. The maximum tensile strain reached in the GFRP SIP form system after 3M cycles was only 11% of its ultimate value.

Journal of Composites for ConstructionVol. 29(1)
Queen's University (CA), Queens University (BD)
Sustainable cities and communities
Openalex Percentile: Top 24%
Structural Behavior of Reinforced Concrete
1.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.