The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs<sup>+</sup> ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs<sup>+</sup> source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ∼2.5-fold increase compared to Cs<sup>+</sup> sources on previous instruments (∼2 pA at 100 nm). The brightness of the new Cs<sup>+</sup> source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-11-26
DOI
https://doi.org/10.1021/acs.analchem.4c03091
Citations
6
Primary Topic
Ion-surface interactions and analysis
Type
article
Field-Weighted Citation Impact
2.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

Jennifer Pett‐Ridge, Ming‐Chang Liu, Rachel Hestrin, Peter Weber et al.
6 citations
Analytical Chemistry
Ion-surface interactions and analysis
2.25
article

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

Jennifer Pett‐Ridge, Ming‐Chang Liu, Rachel Hestrin, Peter Weber, Aurélien Thomen, Reena Zalpuri, Xavier Mayali, L. Arnoldi, Rhona Stuart, Danielle M. Jorgens, Christina Ramon, Megan M. Morris, Jérôme Farcy, Nicolas Saquet, Sarah Vitcher Fichou, Marc Debliqui, Céline Defouilloy, Ludovic Renaud
article en
6 citations

Abstract

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs<sup>+</sup> ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs<sup>+</sup> source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ∼2.5-fold increase compared to Cs<sup>+</sup> sources on previous instruments (∼2 pA at 100 nm). The brightness of the new Cs<sup>+</sup> source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

Analytical ChemistryVol. 96(49)
Lawrence Livermore National Laboratory (US), University of California, Merced (US), University of Massachusetts Amherst (US), Cameca (France) (FR), University of California, Berkeley (US)
Foundation for Food and Agriculture Research, Biological and Environmental Research, Lawrence Livermore National Laboratory
Openalex Percentile: Top 12%
Ion-surface interactions and analysis
2.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.