Bidirectional seismic response of assembled monolithic subway station-aboveground structure system under artificial bedrock ground motions

• Statistical study on vertical and horizontal bedrock ground motion parameters using seismic data. • Empirical relationship between the corner periods of vertical and horizontal response spectra. • Seismic response analysis of assembled monolithic subway station under artificial bedrock ground motions. • Three-dimensional finite element time-history analysis on the seismic response of assembled monolithic subway station. • Effects of vertical ground motion and aboveground structure on the seismic response of assembled monolithic subway station. Assembled monolithic subway station partly synthesizes the advantages of cast-in-place and precast subway stations. However, the related seismic response analysis considering the influences of vertical ground motion and aboveground structure is still scant. In this study, we firstly performed the statistical analysis on bidirectional bedrock ground motion parameters (response spectrum, duration and envelope function) using KiK-net data, and obtained some suggested values of the above parameters. Then, four sets of artificial bedrock ground motions with statistical meanings were generated and a three-dimensional finite element analysis of the seismic response of an existing two-story three-span subway station was conducted. The main results are summarized below. (1) The significant damage to assembled monolithic station under far-field strong motion firstly occurred at side middle slab; middle slab, upper column and related grouting sleeve joints were more damage-prone. (2) When horizontal peak ground acceleration stayed constant, overall the damage of far-field motion was stronger than that of near-fault motion. (3) Vertical ground motion obviously accelerated the damage progresses of various structural members at various positions, then aboveground structure further enhanced the damages and vertical displacement responses of parts of top slab. (4) For the axial force time-history of upper column during far-field strong motion, aboveground structure uplifted the baseline, and vertical ground motion increased the amplitude and advanced the obvious drop of the baseline, among which the latter effect of vertical ground motion on assembled monolithic station was stronger than that on cast-in-place station. (5) Vertical ground motion enhanced inter-story displacement during far-field strong motion, among which the influence on the upper story of assembled monolithic station could be obviously amplified by aboveground structure, and the amplification effect lagged behind the influence of vertical ground motion. Based on the results of this study, some suggestions for the seismic design of subway station are also provided.

Authors

Institutions

Publication Details

Journal
Underground Space
Published
2024-11-26
DOI
https://doi.org/10.1016/j.undsp.2024.08.008
Citations
2
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bidirectional seismic response of assembled monolithic subway station-aboveground structure system under artificial bedrock ground motions

Yang Shi, Hongguang Ji
2 citations
Underground Space
Geotechnical Engineering and Underground Structures
0.52
article

Bidirectional seismic response of assembled monolithic subway station-aboveground structure system under artificial bedrock ground motions

Yang Shi, Hongguang Ji
article en
2 citations

Abstract

• Statistical study on vertical and horizontal bedrock ground motion parameters using seismic data. • Empirical relationship between the corner periods of vertical and horizontal response spectra. • Seismic response analysis of assembled monolithic subway station under artificial bedrock ground motions. • Three-dimensional finite element time-history analysis on the seismic response of assembled monolithic subway station. • Effects of vertical ground motion and aboveground structure on the seismic response of assembled monolithic subway station. Assembled monolithic subway station partly synthesizes the advantages of cast-in-place and precast subway stations. However, the related seismic response analysis considering the influences of vertical ground motion and aboveground structure is still scant. In this study, we firstly performed the statistical analysis on bidirectional bedrock ground motion parameters (response spectrum, duration and envelope function) using KiK-net data, and obtained some suggested values of the above parameters. Then, four sets of artificial bedrock ground motions with statistical meanings were generated and a three-dimensional finite element analysis of the seismic response of an existing two-story three-span subway station was conducted. The main results are summarized below. (1) The significant damage to assembled monolithic station under far-field strong motion firstly occurred at side middle slab; middle slab, upper column and related grouting sleeve joints were more damage-prone. (2) When horizontal peak ground acceleration stayed constant, overall the damage of far-field motion was stronger than that of near-fault motion. (3) Vertical ground motion obviously accelerated the damage progresses of various structural members at various positions, then aboveground structure further enhanced the damages and vertical displacement responses of parts of top slab. (4) For the axial force time-history of upper column during far-field strong motion, aboveground structure uplifted the baseline, and vertical ground motion increased the amplitude and advanced the obvious drop of the baseline, among which the latter effect of vertical ground motion on assembled monolithic station was stronger than that on cast-in-place station. (5) Vertical ground motion enhanced inter-story displacement during far-field strong motion, among which the influence on the upper story of assembled monolithic station could be obviously amplified by aboveground structure, and the amplification effect lagged behind the influence of vertical ground motion. Based on the results of this study, some suggestions for the seismic design of subway station are also provided.

Underground SpaceVol. 21
Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hubei Province
Sustainable cities and communities
Openalex Percentile: Top 35%
Geotechnical Engineering and Underground Structures
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.