Performance evaluation of a brewery wastewater treatment plant: A case of Heineken Brewery, Addis Ababa, Ethiopia

Untreated wastewater from the brewing industry poses significant environmental risks due to its high organic content. Therefore, this study evaluates the wastewater treatment system at Heineken Brewery in Addis Ababa, Ethiopia. Key parameters analyzed include COD, BOD₅, TSS, pH, ammonia (NH₃), total nitrogen (TN), total phosphorus (TP), electrical conductivity (EC), temperature, turbidity, and volatile fatty acids (VFA). These parameters were analyzed following the procedures of the American Public Health Association's standard. The treatment system demonstrated notable efficiency, with influent temperature decreasing from 29.37 °C to 25.35 °C, remaining well below the acceptable limit of 40 °C. The pH dropped from a mean of 9.3 to 7.5, aligning with the acceptable range of 6-9. COD and BOD₅ were significantly reduced by 97.2 %, achieving levels well below discharge limits of 250 mg/L and 60 mg/L, respectively. TSS levels decreased by 95.7 %, with a mean of 32.3 mg/L. However, TP and TN removal efficiencies were lower at 49.4 % and 57.6 %, respectively, with TP slightly exceeding the limit of 5 mg/L. The system effectively reduced VFA by 94.3 % and turbidity by 71.5 %. While parameters such as pH, temperature, TN, NH₄-N, and EC were within acceptable limits, the high nutrient concentrations in the final effluent indicate potential environmental contamination if discharged untreated. Overall, while the treatment plant shows commendable pollutant removal efficiency, further optimization is needed for improved nutrient management.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-11-26
DOI
https://doi.org/10.1016/j.heliyon.2024.e40719
Citations
6
Primary Topic
Wastewater Treatment and Reuse
Type
article
Field-Weighted Citation Impact
1.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of a brewery wastewater treatment plant: A case of Heineken Brewery, Addis Ababa, Ethiopia

Mikiyas Abewaa, Kenatu Angassa, Israel Tessema, Solomon Tibebu et al.
6 citations
Heliyon
Wastewater Treatment and Reuse
1.76
article

Performance evaluation of a brewery wastewater treatment plant: A case of Heineken Brewery, Addis Ababa, Ethiopia

Mikiyas Abewaa, Kenatu Angassa, Israel Tessema, Solomon Tibebu, Tolesa Getu, Teklu Shumbe
article en
6 citations

Abstract

Untreated wastewater from the brewing industry poses significant environmental risks due to its high organic content. Therefore, this study evaluates the wastewater treatment system at Heineken Brewery in Addis Ababa, Ethiopia. Key parameters analyzed include COD, BOD₅, TSS, pH, ammonia (NH₃), total nitrogen (TN), total phosphorus (TP), electrical conductivity (EC), temperature, turbidity, and volatile fatty acids (VFA). These parameters were analyzed following the procedures of the American Public Health Association's standard. The treatment system demonstrated notable efficiency, with influent temperature decreasing from 29.37 °C to 25.35 °C, remaining well below the acceptable limit of 40 °C. The pH dropped from a mean of 9.3 to 7.5, aligning with the acceptable range of 6-9. COD and BOD₅ were significantly reduced by 97.2 %, achieving levels well below discharge limits of 250 mg/L and 60 mg/L, respectively. TSS levels decreased by 95.7 %, with a mean of 32.3 mg/L. However, TP and TN removal efficiencies were lower at 49.4 % and 57.6 %, respectively, with TP slightly exceeding the limit of 5 mg/L. The system effectively reduced VFA by 94.3 % and turbidity by 71.5 %. While parameters such as pH, temperature, TN, NH₄-N, and EC were within acceptable limits, the high nutrient concentrations in the final effluent indicate potential environmental contamination if discharged untreated. Overall, while the treatment plant shows commendable pollutant removal efficiency, further optimization is needed for improved nutrient management.

HeliyonVol. 10(23)
Ethiopian Civil Service University (ET), Addis Ababa Science and Technology University (ET), Wachemo University
Clean water and sanitation
Openalex Percentile: Top 16%
Wastewater Treatment and Reuse
1.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.