Diamond-coated quartz crystal microbalance sensors: Challenges in high yield production and enhanced detection of ethanol and sars-cov-2 proteins

• Low-temperature MWCVD synthesis of porous and fully closed diamond films on QCM. • Double-sided diamond-QCM shows 12-fold enhancement in ethanol vapor sensitivity. • Single-sided diamond-QCM shows a 2-fold higher response for S-RBD protein detection. • Diamond-QCM demonstrates selective detection of S-RBD protein over N-protein. • Diamond-QCM achieves a 10% lower detection limit for S-RBD protein versus bare QCM. This study presents the technological progress in the deposition of diamond thin films on quartz crystal microbalance (QCM) sensors. The linear antenna microwave plasma chemical vapour deposition (CVD) technique effectively grows thin diamond films on QCM substrates (Dia-QCM) differently oriented on the substrate holder in the deposition chamber, resulting in single-sided and double-sided coated QCMs. Each of these coated QCMs offers a distinctive advantage for sensing applications. The double-sided coated QCM sensors exhibited the most effective performance in ethanol detection, demonstrating approx. a 3-fold and 12-fold higher response than single-sided diamond-coated and bare gold QCM sensors, respectively. Furthermore, the single-sided Dia-QCM aptasensors demonstrated superior performance compared to bare gold QCM sensors, with a 2-fold higher response and a lower detection limit for S-RBD protein (LOD Dia-QCM = 0.09 pg/mL vs. LOD Au-QCM = 0.10 pg/mL). In experiments conducted in human plasma, the Dia-QCM aptasensor demonstrated the ability to detect S-RBD protein at concentrations as low as 50 pg/mL, with high percentage recoveries. These results highlight the potential of linear antenna microwave plasma CVD for the mass production of advanced diamond-coated QCM sensors with different diamond film morphologies (porous, micro- or nanocrystalline) for various applications.

Authors

Publication Details

Journal
Materials & Design
Published
2024-11-26
DOI
https://doi.org/10.1016/j.matdes.2024.113474
Citations
2
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diamond-coated quartz crystal microbalance sensors: Challenges in high yield production and enhanced detection of ethanol and sars-cov-2 proteins

Ondrej Szabó, Tibor Izsák, Alexander Kromka, Miroslav Gál et al.
2 citations
Materials & Design
Acoustic Wave Resonator Technologies
0.37
article

Diamond-coated quartz crystal microbalance sensors: Challenges in high yield production and enhanced detection of ethanol and sars-cov-2 proteins

Ondrej Szabó, Tibor Izsák, Alexander Kromka, Miroslav Gál, M. Varga, Kateřina Aubrechtová Dragounová, Alexandra Poturnayová, G. Vanko, Michal Kočí, Jana Korčeková, Michaela Hornychová
article en
2 citations

Abstract

• Low-temperature MWCVD synthesis of porous and fully closed diamond films on QCM. • Double-sided diamond-QCM shows 12-fold enhancement in ethanol vapor sensitivity. • Single-sided diamond-QCM shows a 2-fold higher response for S-RBD protein detection. • Diamond-QCM demonstrates selective detection of S-RBD protein over N-protein. • Diamond-QCM achieves a 10% lower detection limit for S-RBD protein versus bare QCM. This study presents the technological progress in the deposition of diamond thin films on quartz crystal microbalance (QCM) sensors. The linear antenna microwave plasma chemical vapour deposition (CVD) technique effectively grows thin diamond films on QCM substrates (Dia-QCM) differently oriented on the substrate holder in the deposition chamber, resulting in single-sided and double-sided coated QCMs. Each of these coated QCMs offers a distinctive advantage for sensing applications. The double-sided coated QCM sensors exhibited the most effective performance in ethanol detection, demonstrating approx. a 3-fold and 12-fold higher response than single-sided diamond-coated and bare gold QCM sensors, respectively. Furthermore, the single-sided Dia-QCM aptasensors demonstrated superior performance compared to bare gold QCM sensors, with a 2-fold higher response and a lower detection limit for S-RBD protein (LOD Dia-QCM = 0.09 pg/mL vs. LOD Au-QCM = 0.10 pg/mL). In experiments conducted in human plasma, the Dia-QCM aptasensor demonstrated the ability to detect S-RBD protein at concentrations as low as 50 pg/mL, with high percentage recoveries. These results highlight the potential of linear antenna microwave plasma CVD for the mass production of advanced diamond-coated QCM sensors with different diamond film morphologies (porous, micro- or nanocrystalline) for various applications.

Materials & DesignVol. 248
České Vysoké Učení Technické v Praze, Slovenská Akadémia Vied, Ministerstvo Školství, Mládeže a Tělovýchovy, Grantová Agentura České Republiky, Ministerstvo školstva, vedy, výskumu a športu Slovenskej republiky, Akademie Věd České Republiky, Narodowe Centrum Nauki, Vedecká Grantová Agentúra MŠVVaŠ SR a SAV, Agentúra Ministerstva Školstva, Vedy, Výskumu a Športu SR
Openalex Percentile: Top 42%
Acoustic Wave Resonator Technologies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.