Continuous Flow Chemistry and Bayesian Optimization for Polymer-Functionalized Carbon Nanotube-Based Chemiresistive Methane Sensors

We report the preparation of poly(ionic) polymer-wrapped single-walled carbon nanotube dispersions for chemiresistive methane (CH<sub>4</sub>) sensors with improved humidity tolerance. Single-walled CNTs (SWCNTs) were noncovalently functionalized by poly(4-vinylpyridine) (P4VP) with varied amounts of a poly(ethylene glycol) (PEG) moiety bearing a Br and terminal azide group (Br-R<sub>1</sub>). The quaternization of P4VP with Br-R<sub>1</sub> was performed using continuous flow chemistry and Bayesian optimization-guided reaction selection. Polymers (PyBrR<sub>1</sub>) with different degrees of functionalization were used to disperse SWCNTs and subsequently incorporated into sensors containing a platinum complex as an aerobic oxidative catalyst with a polyoxometalate (POM) redox mediator to facilitate room-temperature CH<sub>4</sub> sensing. As the degree of quaternization in the PyBrR<sub>1</sub>-CNT composites increased, improvements in response magnitude were observed, with nominally 10% quaternized PyBrR<sub>1</sub> giving the largest response. Incorporation of PEG improved sensor stability at relative humidities between 57-90% versus sensors fabricated from CNT dispersions with unfunctionalized P4VP. Devices fabricated with these dispersions outperformed those prepared in situ under dry conditions, and exhibited greater stability at elevated humidities. The influence of Keggin-type POM character was also evaluated to identify alternative POMs for enhanced sensor performance at high humidity. In an effort to identify areas for further improvement in algorithm performance for polymer functionalization, a kinetically informed machine learning model was explored as a route to predict reactivity of pyridine units and alkyl bromides under flow conditions.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-11-26
DOI
https://doi.org/10.1021/acsami.4c14279
Citations
4
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Flow Chemistry and Bayesian Optimization for Polymer-Functionalized Carbon Nanotube-Based Chemiresistive Methane Sensors

Ly D. Tran, John H. Dunlap, Christopher A. Crouse, Rahul Rao et al.
4 citations
ACS Applied Materials & Interfaces
Innovative Microfluidic and Catalytic Techniques Innovation
0.74
article

Continuous Flow Chemistry and Bayesian Optimization for Polymer-Functionalized Carbon Nanotube-Based Chemiresistive Methane Sensors

Ly D. Tran, John H. Dunlap, Christopher A. Crouse, Rahul Rao, Amanda A. Volk, Luke A. Baldwin, Timothy M. Swager, Haosheng Feng, Cheri M. Hampton, Shao‐Xiong Lennon Luo, Andrea N. Giordano, Alexander Reidell, Thomas N. Pioch
article en
4 citations

Abstract

We report the preparation of poly(ionic) polymer-wrapped single-walled carbon nanotube dispersions for chemiresistive methane (CH<sub>4</sub>) sensors with improved humidity tolerance. Single-walled CNTs (SWCNTs) were noncovalently functionalized by poly(4-vinylpyridine) (P4VP) with varied amounts of a poly(ethylene glycol) (PEG) moiety bearing a Br and terminal azide group (Br-R<sub>1</sub>). The quaternization of P4VP with Br-R<sub>1</sub> was performed using continuous flow chemistry and Bayesian optimization-guided reaction selection. Polymers (PyBrR<sub>1</sub>) with different degrees of functionalization were used to disperse SWCNTs and subsequently incorporated into sensors containing a platinum complex as an aerobic oxidative catalyst with a polyoxometalate (POM) redox mediator to facilitate room-temperature CH<sub>4</sub> sensing. As the degree of quaternization in the PyBrR<sub>1</sub>-CNT composites increased, improvements in response magnitude were observed, with nominally 10% quaternized PyBrR<sub>1</sub> giving the largest response. Incorporation of PEG improved sensor stability at relative humidities between 57-90% versus sensors fabricated from CNT dispersions with unfunctionalized P4VP. Devices fabricated with these dispersions outperformed those prepared in situ under dry conditions, and exhibited greater stability at elevated humidities. The influence of Keggin-type POM character was also evaluated to identify alternative POMs for enhanced sensor performance at high humidity. In an effort to identify areas for further improvement in algorithm performance for polymer functionalization, a kinetically informed machine learning model was explored as a route to predict reactivity of pyridine units and alkyl bromides under flow conditions.

ACS Applied Materials & InterfacesVol. 16(49)
United States Air Force Research Laboratory (US), National Academies of Sciences, Engineering, and Medicine (US), Massachusetts Institute of Technology (US)
National Science Foundation, U.S. Department of Defense, Harvard University, National Academies of Sciences, Engineering, and Medicine, Office of Naval Research, Division of Materials Research, Division of Electrical, Communications and Cyber Systems
Openalex Percentile: Top 31%
Innovative Microfluidic and Catalytic Techniques Innovation
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.