Unveiling stimulus transduction artifacts in auditory steady-state response experiments: Characterization, risks, and mitigation strategies

This scientific paper addresses the potential risk of spurious responses in neuroscientific auditory steady-state response (ASSR) experiments attributed to transduction artifacts. The focus is particularly on click train stimuli, given their spectral content in the frequency range of interest (e.g., 40 Hz). Building upon a pilot experiment demonstrating the existence of the artifact in a phantom head, this study focuses on the characterization of stimulus artifacts in extended measurements with phantoms and the evaluation of associated risks in experiments involving human subjects, where 15 subjects were stimulated by headphones and speakers, which served as a control condition. The investigation is divided into two parts: the first part scrutinizes stimulus artifact properties crucial for mitigation, while the second part assesses risks in ASSR experiments with human subjects based on the characterized artifact. The discussion covers stimulus characterization, experimental setups with phantoms, and experiments with human subjects, exploring potential sources of the artifact, its spatial properties, and the influence of re-referencing, which can suppress a less prominent artifact while significantly increasing the prominent and focused artifact. The results reveal the role of headphone cables as a source of stimulus artifacts, along with the surprising impact of headphone transducers. The study emphasizes the need for careful experimental design. We proposes specific data analyses assessing cross-frequency correlation maps and the topographic structure of the brain response at higher harmonic frequencies of the fundamental 40 Hz component. These steps, if applied appropriately, will prevent misinterpretation of stimulus artifacts as genuine brain responses in ASSR experiments. • Identified stimulus artifacts in auditory steady-state response (ASSR) experiments, particularly with click train stimuli. • Characterized stimulus artifacts using extended measurements with human head phantoms and human subjects. • Revealed headphone cables and transducers as sources of stimulus artifacts in EEG data during ASSR experiments. • Demonstrated that artifacts are not prominent at 40 Hz but may appear in higher harmonic frequencies, such as 120 Hz. • Proposed cross-frequency correlation maps and topographic analyses to prevent misinterpretation of artifacts as genuine brain responses.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2024-11-26
DOI
https://doi.org/10.1016/j.bspc.2024.107128
Primary Topic
Neural dynamics and brain function
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Unveiling stimulus transduction artifacts in auditory steady-state response experiments: Characterization, risks, and mitigation strategies

Jan Hubený, Tomáš Páleníček, Vlastimil Koudelka, Jan Štrobl et al.
Biomedical Signal Processing and Control
Neural dynamics and brain function
article

Unveiling stimulus transduction artifacts in auditory steady-state response experiments: Characterization, risks, and mitigation strategies

Jan Hubený, Tomáš Páleníček, Vlastimil Koudelka, Jan Štrobl, Marek Piorecký, Martin Brunovský, Inga Griškova-Bulanova, Vojtěch Viktorin
article en

Abstract

This scientific paper addresses the potential risk of spurious responses in neuroscientific auditory steady-state response (ASSR) experiments attributed to transduction artifacts. The focus is particularly on click train stimuli, given their spectral content in the frequency range of interest (e.g., 40 Hz). Building upon a pilot experiment demonstrating the existence of the artifact in a phantom head, this study focuses on the characterization of stimulus artifacts in extended measurements with phantoms and the evaluation of associated risks in experiments involving human subjects, where 15 subjects were stimulated by headphones and speakers, which served as a control condition. The investigation is divided into two parts: the first part scrutinizes stimulus artifact properties crucial for mitigation, while the second part assesses risks in ASSR experiments with human subjects based on the characterized artifact. The discussion covers stimulus characterization, experimental setups with phantoms, and experiments with human subjects, exploring potential sources of the artifact, its spatial properties, and the influence of re-referencing, which can suppress a less prominent artifact while significantly increasing the prominent and focused artifact. The results reveal the role of headphone cables as a source of stimulus artifacts, along with the surprising impact of headphone transducers. The study emphasizes the need for careful experimental design. We proposes specific data analyses assessing cross-frequency correlation maps and the topographic structure of the brain response at higher harmonic frequencies of the fundamental 40 Hz component. These steps, if applied appropriately, will prevent misinterpretation of stimulus artifacts as genuine brain responses in ASSR experiments. • Identified stimulus artifacts in auditory steady-state response (ASSR) experiments, particularly with click train stimuli. • Characterized stimulus artifacts using extended measurements with human head phantoms and human subjects. • Revealed headphone cables and transducers as sources of stimulus artifacts in EEG data during ASSR experiments. • Demonstrated that artifacts are not prominent at 40 Hz but may appear in higher harmonic frequencies, such as 120 Hz. • Proposed cross-frequency correlation maps and topographic analyses to prevent misinterpretation of artifacts as genuine brain responses.

Biomedical Signal Processing and ControlVol. 101
Vilnius University (LT), Charles University (CZ), National Institute of Mental Health (CZ), Czech Technical University in Prague (CZ)
Climate action
Openalex Percentile: Top 78%
Neural dynamics and brain function
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.