Blast mitigation using low-density EPS concrete: An experimental study

This paper reports the results from an experimental study on the blast loading of low-density expanded polystyrene (EPS) concrete used for mitigation purpose. A volume fraction of 75 % is considered for the EPS. The effect of the presence of a front plate, attached to the tested EPS concrete sample, is analysed. Four blast intensities, generated at the end section of an explosive-driven shock tube (EDST), are used. Impulses are between 7.7 and 16 N.s. A small-scale experimental set-up is developed allowing the measurement of the transmitted impulse to an instrumented free-moving rigid plate. This transmitted impulse is quantified with three independent devices: pressure transducers, a high-speed camera (HSC) and an accelerometer. The experimental results show two distinct behaviour patterns of the EPS concrete: (i) crushing, and (ii) pulverization. The use of a front plate leads to a uniform loading on the front section of the specimen and a gradual crushing of the material. Without the presence of a front plate, the specimen is immediately exposed to the blast wave, leading to a pulverization process which allows an impulse reduction by 50 %.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2024-11-26
DOI
https://doi.org/10.1016/j.cscm.2024.e03962
Citations
3
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blast mitigation using low-density EPS concrete: An experimental study

Bachir Belkassem, David Lecompte, Hamza Ousji, Karim Miled et al.
3 citations
Case Studies in Construction Materials
Structural Response to Dynamic Loads
0.78
article

Blast mitigation using low-density EPS concrete: An experimental study

Bachir Belkassem, David Lecompte, Hamza Ousji, Karim Miled, Ahmed Siala
article en
3 citations

Abstract

This paper reports the results from an experimental study on the blast loading of low-density expanded polystyrene (EPS) concrete used for mitigation purpose. A volume fraction of 75 % is considered for the EPS. The effect of the presence of a front plate, attached to the tested EPS concrete sample, is analysed. Four blast intensities, generated at the end section of an explosive-driven shock tube (EDST), are used. Impulses are between 7.7 and 16 N.s. A small-scale experimental set-up is developed allowing the measurement of the transmitted impulse to an instrumented free-moving rigid plate. This transmitted impulse is quantified with three independent devices: pressure transducers, a high-speed camera (HSC) and an accelerometer. The experimental results show two distinct behaviour patterns of the EPS concrete: (i) crushing, and (ii) pulverization. The use of a front plate leads to a uniform loading on the front section of the specimen and a gradual crushing of the material. Without the presence of a front plate, the specimen is immediately exposed to the blast wave, leading to a pulverization process which allows an impulse reduction by 50 %.

Case Studies in Construction MaterialsVol. 21
Tunis University (TN), Royal Military Academy (BE), National Engineering School of Tunis (TN), Military Hospital of Tunis (TN), Tunis El Manar University (TN)
Climate action
Openalex Percentile: Top 29%
Structural Response to Dynamic Loads
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.