Wearable sensing systems have been designed to monitor health conditions in real-time by detecting analytes in human biofluids. Wound diagnosis remains challenging, necessitating suitable materials for high-performance wearable sensors to offer prompt feedback. Existing devices have limitations in measuring pH and the concentration of pH-dependent electroactive species simultaneously, which is crucial for obtaining a comprehensive understanding of wound status and optimizing biosensors. Therefore, improving materials and analysis system accuracy is essential. This article introduces the first example of a flexible array capable of detecting pyocyanin, a bacterial virulence factor, while correcting dynamic pH fluctuations. We demonstrate that this combined sensor enhances accuracy by mitigating the impact of pH variability on pyocyanin sensor response. Customized screen-printable inks were developed to enhance analytical performance. The analytical performances of two sensitive sensor systems (i.e., fully-printed porous graphene/multiwalled carbon nanotube (CNT) and polyaniline/CNT composites for pyocyanin and pH sensors) are evaluated. Partial least square regression is employed to analyze nonzero-order data arrays from square wave voltammetric and potentiometric measurements of pyocyanin and pH sensors to establish a predictive model for pyocyanin concentration in complex fluids. This sensitive and effective strategy shows potential for personalized applications due to its affordability, ease of use, and ability to adjust for dynamic pH changes.

Authors

Institutions

Publication Details

Journal
Nano-Micro Letters
Published
2024-11-26
DOI
https://doi.org/10.1007/s40820-024-01561-8
Citations
34
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
9.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fully-Printed Wearable Bandage-Based Electrochemical Sensor with pH Correction for Wound Infection Monitoring

Kornautchaya Veenuttranon, Kanyawee Kaewpradub, Pimonsri Mittraparp‐arthorn, Itthipon Jeerapan et al.
34 citations
Nano-Micro Letters
Analytical Chemistry and Sensors
9.82
article

A Fully-Printed Wearable Bandage-Based Electrochemical Sensor with pH Correction for Wound Infection Monitoring

Kornautchaya Veenuttranon, Kanyawee Kaewpradub, Pimonsri Mittraparp‐arthorn, Itthipon Jeerapan, Husanai Jantapaso
article en
34 citations

Abstract

Wearable sensing systems have been designed to monitor health conditions in real-time by detecting analytes in human biofluids. Wound diagnosis remains challenging, necessitating suitable materials for high-performance wearable sensors to offer prompt feedback. Existing devices have limitations in measuring pH and the concentration of pH-dependent electroactive species simultaneously, which is crucial for obtaining a comprehensive understanding of wound status and optimizing biosensors. Therefore, improving materials and analysis system accuracy is essential. This article introduces the first example of a flexible array capable of detecting pyocyanin, a bacterial virulence factor, while correcting dynamic pH fluctuations. We demonstrate that this combined sensor enhances accuracy by mitigating the impact of pH variability on pyocyanin sensor response. Customized screen-printable inks were developed to enhance analytical performance. The analytical performances of two sensitive sensor systems (i.e., fully-printed porous graphene/multiwalled carbon nanotube (CNT) and polyaniline/CNT composites for pyocyanin and pH sensors) are evaluated. Partial least square regression is employed to analyze nonzero-order data arrays from square wave voltammetric and potentiometric measurements of pyocyanin and pH sensors to establish a predictive model for pyocyanin concentration in complex fluids. This sensitive and effective strategy shows potential for personalized applications due to its affordability, ease of use, and ability to adjust for dynamic pH changes.

Nano-Micro LettersVol. 17(1)
Prince of Songkla University (TH)
Prince of Songkla University, Ministry of Higher Education, Science, Research and Innovation, Thailand, Center of Excellence for Innovation in Chemistry
Openalex Percentile: Top 1%
Analytical Chemistry and Sensors
9.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.