Modeling Airflow and Temperature in a Sealed Cold Storage System for Medicinal Plant Cultivation Using Computational Fluid Dynamics (CFD)

Effective air circulation is crucial for plant growth, requiring adequate airflow and environmental stability. This study utilized Computational Fluid Dynamics (CFD) to analyze airflow patterns in a controlled testing chamber, focusing on how miniature fan placement affects airflow direction and temperature distribution. Ten case studies were conducted, with the CFD model validated against experimental data collected from six monitoring locations on the plant growth table. Model validation was performed using statistical analyses including coefficient of determination (R2), root mean square error (RMSE), and mean absolute error (MAE). The validation results showed strong agreement between simulated and experimental data, with R2 values of 0.92 for temperature and 0.89 for airflow velocity. Statistical analysis showed significant differences in both airflow and temperature models at the 0.05 level, with the CFD model validation yielding an RMSE of 2.02 and an average absolute error of 1.17. Among the tested configurations, case M1 achieved the highest air velocity (0.317 m/s) and lowest temperature (27.03 °C), compared to M2 (0.255 m/s, 27.17 °C) and M3 (0.164 m/s, 27.18 °C). The temperature variations between cases significantly impacted cold storage efficiency, with case M1’s superior airflow distribution providing more uniform cooling. These findings offer practical guidelines for optimizing ventilation system design in medicinal plant cultivation facilities, particularly in maintaining ideal storage conditions through strategic fan placement and airflow management.

Authors

Institutions

Publication Details

Journal
Agronomy
Published
2024-11-26
DOI
https://doi.org/10.3390/agronomy14122808
Citations
3
Primary Topic
Greenhouse Technology and Climate Control
Type
article
Field-Weighted Citation Impact
1.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling Airflow and Temperature in a Sealed Cold Storage System for Medicinal Plant Cultivation Using Computational Fluid Dynamics (CFD)

Sakkarin Wangkahart, Kaweepong Hongtong, Aphichat Srichat, Somporn Katekaew et al.
3 citations
Agronomy
Greenhouse Technology and Climate Control
1.80
article

Modeling Airflow and Temperature in a Sealed Cold Storage System for Medicinal Plant Cultivation Using Computational Fluid Dynamics (CFD)

Sakkarin Wangkahart, Kaweepong Hongtong, Aphichat Srichat, Somporn Katekaew, Chaiyan Junsiri, Kittipong Laloon, Sahassawas Poojeera, Phaiboon Boupha
article en
3 citations

Abstract

Effective air circulation is crucial for plant growth, requiring adequate airflow and environmental stability. This study utilized Computational Fluid Dynamics (CFD) to analyze airflow patterns in a controlled testing chamber, focusing on how miniature fan placement affects airflow direction and temperature distribution. Ten case studies were conducted, with the CFD model validated against experimental data collected from six monitoring locations on the plant growth table. Model validation was performed using statistical analyses including coefficient of determination (R2), root mean square error (RMSE), and mean absolute error (MAE). The validation results showed strong agreement between simulated and experimental data, with R2 values of 0.92 for temperature and 0.89 for airflow velocity. Statistical analysis showed significant differences in both airflow and temperature models at the 0.05 level, with the CFD model validation yielding an RMSE of 2.02 and an average absolute error of 1.17. Among the tested configurations, case M1 achieved the highest air velocity (0.317 m/s) and lowest temperature (27.03 °C), compared to M2 (0.255 m/s, 27.17 °C) and M3 (0.164 m/s, 27.18 °C). The temperature variations between cases significantly impacted cold storage efficiency, with case M1’s superior airflow distribution providing more uniform cooling. These findings offer practical guidelines for optimizing ventilation system design in medicinal plant cultivation facilities, particularly in maintaining ideal storage conditions through strategic fan placement and airflow management.

AgronomyVol. 14(12)
Khon Kaen University (TH), Udon Thani Rajabhat University (TH), Postharvest Technology Innovation Center
Openalex Percentile: Top 13%
Greenhouse Technology and Climate Control
1.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.