Improved Lateral Resistance Test: Investigating the Effect of a Partial Uplift Restraint during a Single Sleeper Push Test

Conventional railway sleeper (tie) lateral resistance tests often assess small lateral displacements (∼2 mm) and do not consider the vertical displacement (uplift) of sleepers through lateral plane rotation which, for installed sleepers, is constrained by the supported rail. Consequently, unrestrained tests tend to underpredict the lateral resistance achievable in service. This paper describes an alternative single sleeper push test (SSPT) methodology in which railway sleepers are restrained during laboratory lateral resistance tests, with a passive restraint system used to limit sleeper uplift. The lateral resistance of concrete and steel sleepers has been investigated using a SSPT in a ballast box with and without the use of the new restraint system. It has been found that, when unconstrained, both concrete and steel sleepers uplift, with the greatest uplift values seen for steel sleepers. In the more realistic restrained configuration, the lateral resistance of the concrete sleeper increased. The steel sleeper saw an even greater increase in lateral resistance and furthermore experienced a rising lateral resistance with increasing lateral displacements. An existing model was used, and expanded, to predict the buckling stability of track for both restraint conditions, with significantly lower minimum buckling temperatures found for both sleeper types when free to uplift. This study shows that partial restraint of sleepers, as imposed by the rail in track, has a tangible influence on the sleeper lateral resistance during push tests compared with unrestrained tests. The results of this study enhance the understanding of sleeper behavior during lateral track shifts, which has the potential to improve buckling risk mitigation strategies.

Authors

Institutions

Publication Details

Journal
Transportation Research Record Journal of the Transportation Research Board
Published
2024-11-26
DOI
https://doi.org/10.1177/03611981241295705
Citations
3
Primary Topic
Railway Engineering and Dynamics
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Lateral Resistance Test: Investigating the Effect of a Partial Uplift Restraint during a Single Sleeper Push Test

Jacob W. Whittle, Inna M. Gitman, David I Fletcher, Iwo Słodczyk et al.
3 citations
Transportation Research Record Journal of the Transportation Research Board
Railway Engineering and Dynamics
0.64
article

Improved Lateral Resistance Test: Investigating the Effect of a Partial Uplift Restraint during a Single Sleeper Push Test

Jacob W. Whittle, Inna M. Gitman, David I Fletcher, Iwo Słodczyk, Stephen Danks, Brian Whitney
article en
3 citations

Abstract

Conventional railway sleeper (tie) lateral resistance tests often assess small lateral displacements (∼2 mm) and do not consider the vertical displacement (uplift) of sleepers through lateral plane rotation which, for installed sleepers, is constrained by the supported rail. Consequently, unrestrained tests tend to underpredict the lateral resistance achievable in service. This paper describes an alternative single sleeper push test (SSPT) methodology in which railway sleepers are restrained during laboratory lateral resistance tests, with a passive restraint system used to limit sleeper uplift. The lateral resistance of concrete and steel sleepers has been investigated using a SSPT in a ballast box with and without the use of the new restraint system. It has been found that, when unconstrained, both concrete and steel sleepers uplift, with the greatest uplift values seen for steel sleepers. In the more realistic restrained configuration, the lateral resistance of the concrete sleeper increased. The steel sleeper saw an even greater increase in lateral resistance and furthermore experienced a rising lateral resistance with increasing lateral displacements. An existing model was used, and expanded, to predict the buckling stability of track for both restraint conditions, with significantly lower minimum buckling temperatures found for both sleeper types when free to uplift. This study shows that partial restraint of sleepers, as imposed by the rail in track, has a tangible influence on the sleeper lateral resistance during push tests compared with unrestrained tests. The results of this study enhance the understanding of sleeper behavior during lateral track shifts, which has the potential to improve buckling risk mitigation strategies.

Transportation Research Record Journal of the Transportation Research BoardVol. 2679(4)
British Steel (United Kingdom) (GB), Network Rail (GB), University of Sheffield (GB), University of Twente (NL)
Openalex Percentile: Top 34%
Railway Engineering and Dynamics
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.