Antitumor effects of plasma‑activated solution on a murine melanoma model <i>in vivo</i> and <i>in vitro</i>
Melanoma is a common malignant skin tumor with highly invasive features and a high metastasis rate that can be difficult to treat clinically. Large-scale resection of primary cutaneous melanoma is often used to avoid postoperative recurrence. For advanced patients, radiotherapy, targeted therapy and immunotherapy are often needed. Low-temperature plasma has been proved to have significant antitumor effects on a variety of cancer cell lines cultured <i>in vitro</i>. The main limitation of direct low-temperature plasma treatment is that it has weak penetration ability and can only treat superficial lesions. In recent years, research on low-temperature plasma-activated solution has revealed that it also have good antitumor effects and low-temperature plasma penetration depth problems can be solved by local injection. The present study revealed that low-temperature plasma-activated phosphate buffer solution exhibited good antitumor effects and biosafety against melanoma <i>in vitro</i> and <i>in vivo</i>. It demonstrated that low-temperature plasma-activated solution has antitumor effects due to its regulation of intracellular redox, destruction of mitochondrial function and DNA damage. <i>In vivo</i> experiments demonstrated that treatment with low-temperature plasma-activated solution not only exhibited antitumor effects but also caused no significant damage to hematopoietic function or liver and kidney functions in mice. All these results demonstrated that low-temperature plasma-activated solution represent a promising antitumor treatment strategy.
Authors
- Cheng Cheng (ORCID: https://orcid.org/0000-0002-5007-4695)
- Chenchen Zhang (ORCID: https://orcid.org/0000-0001-8206-2210)
- Cheng Chen (ORCID: https://orcid.org/0000-0002-7323-1104)
- Shiyun Zhou
- Chunjun Yang (ORCID: https://orcid.org/0000-0003-1887-7735)
- Xingyu Yang (ORCID: https://orcid.org/0000-0002-3266-7542)
- Miaomiao Ren
Institutions
- Anhui Medical University (CN)
- Institute of Plasma Physics (CN)
- Second Affiliated Hospital of Anhui Medical University (CN)
Publication Details
- Journal
- Oncology Letters
- Published
- 2024-11-26
- DOI
- https://doi.org/10.3892/ol.2024.14821
- Citations
- 7
- Primary Topic
- Plasma Applications and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 2.83
Funders
- Chinese Academy of Sciences
- Anhui Medical University
- Hefei Institutes of Physical Science, Chinese Academy of Sciences