Multi-Objective Optimization of Outdoor Thermal Comfort and Sunlight Hours in Elderly Residential Areas: A Case Study of Beijing, China

To optimize the outdoor thermal comfort and sunlight hours of elderly residential areas in cold regions of China, we collected data on streets and building forms from 121 elderly residential sites in Beijing. Utilizing parametric modeling tools to generate ideal residential models, a multi-objective optimization algorithm was applied to identify 144 Pareto solutions. The optimal solutions were analyzed using K-means clustering and Pearson correlation analysis to examine how block form affects outdoor environmental performance. The universal thermal climate index (UTCI) in summer showed significant positive correlations (r > 0.72) with the distance between buildings (DB), building density (BD), shape coefficient (SC), and coefficient of variation for building height (CVH), and significant negative correlations (r < −0.82) with average building height (AH), floor area ratio (FAR), volume area ratio (VAR), mean building area (MA), average building volume (AV), and open space ratio (OSR). Winter UTCI was significantly positively correlated with AH, FAR, VAR, MA, and AV (r > 0.83) and significantly negatively correlated with DB, porosity (PO), SC, and CVH (r < −0.88). Sunlight hours were significantly positively correlated with DB, PO, OSR, and CVH (r > 0.84) and significantly negatively correlated with AH, BD, FAR, SC, VAR, MA, and AV (r > 0.88). Courtyard and point-building configurations performed the best across all optimization objectives. (The value of r, Pearson’s correlation coefficient, ranges from −1 to +1. r = +1: Perfect positive correlation, r = −1: Perfect negative correlation, r = 0: No linear correlation).

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-26
DOI
https://doi.org/10.3390/buildings14123770
Citations
9
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
2.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Objective Optimization of Outdoor Thermal Comfort and Sunlight Hours in Elderly Residential Areas: A Case Study of Beijing, China

Hainan Yan, Ling Jiang, Z. H. Zhang, Deqing Bu et al.
9 citations
Buildings
Building Energy and Comfort Optimization
2.39
article

Multi-Objective Optimization of Outdoor Thermal Comfort and Sunlight Hours in Elderly Residential Areas: A Case Study of Beijing, China

Hainan Yan, Ling Jiang, Z. H. Zhang, Deqing Bu, Lu Zhang, X. X. Ding, Zhenze Qi
article en
9 citations

Abstract

To optimize the outdoor thermal comfort and sunlight hours of elderly residential areas in cold regions of China, we collected data on streets and building forms from 121 elderly residential sites in Beijing. Utilizing parametric modeling tools to generate ideal residential models, a multi-objective optimization algorithm was applied to identify 144 Pareto solutions. The optimal solutions were analyzed using K-means clustering and Pearson correlation analysis to examine how block form affects outdoor environmental performance. The universal thermal climate index (UTCI) in summer showed significant positive correlations (r > 0.72) with the distance between buildings (DB), building density (BD), shape coefficient (SC), and coefficient of variation for building height (CVH), and significant negative correlations (r < −0.82) with average building height (AH), floor area ratio (FAR), volume area ratio (VAR), mean building area (MA), average building volume (AV), and open space ratio (OSR). Winter UTCI was significantly positively correlated with AH, FAR, VAR, MA, and AV (r > 0.83) and significantly negatively correlated with DB, porosity (PO), SC, and CVH (r < −0.88). Sunlight hours were significantly positively correlated with DB, PO, OSR, and CVH (r > 0.84) and significantly negatively correlated with AH, BD, FAR, SC, VAR, MA, and AV (r > 0.88). Courtyard and point-building configurations performed the best across all optimization objectives. (The value of r, Pearson’s correlation coefficient, ranges from −1 to +1. r = +1: Perfect positive correlation, r = −1: Perfect negative correlation, r = 0: No linear correlation).

BuildingsVol. 14(12)
North China University of Technology (CN), Nanjing University (CN)
Climate action
Openalex Percentile: Top 12%
Building Energy and Comfort Optimization
2.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.