Application of Golay-based total focusing method using a high-frequency, lead-free, flexible ultrasonic array for inspection of thick non-planar industrial components

The compromise between axial resolution and penetration depth in ultrasound imaging poses a challenge for high-frequency ultrasonic arrays, limiting their ability to effectively inspect thick components in industrial applications. In this work, a commercial 20 MHz, 64 element, 1 mm pitch lead-free flexible linear array was characterised in terms of its performance. The array was subsequently evaluated using Golay-coded excitation techniques to enhance the signal-to-noise ratio (SNR) and operability on non-planar thick components. The SNR improvement verification results were acquired with the array deployed on a 100 mm thick flat aluminium test specimen. As expected, an increase in SNR was observed as the Golay code length increased. The imaging strategy employed a combination of Full Matrix Capture (FMC) and Total Focusing Method (TFM) to assess the performance variations between the conventional pulse excitation and Golay-coded excitation. The Golay-based TFM demonstrated superior performance compared to the conventional pulse-based TFM, with an SNR improvement of 4.95 dB when using the full array aperture to inspect the non-planar steel S355 specimen. A sub-aperture selection approach, based on the effect of the array element beam spread, offered additional SNR improvement of up to 8.2 dB. Greater imaging penetration depth was achieved, with an increase of >40 % compared to conventional pulse-based TFM. Thus, for inspection of thick non-planar industrial components using a lead-free high-frequency array, Golay-coded excitation schemes show excellent potential to enhance SNR, penetration depth and imaging quality.

Authors

Institutions

Publication Details

Journal
NDT & E International
Published
2024-11-25
DOI
https://doi.org/10.1016/j.ndteint.2024.103282
Citations
4
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
1.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Golay-based total focusing method using a high-frequency, lead-free, flexible ultrasonic array for inspection of thick non-planar industrial components

Heather Trodden, David Lines, Charles MacLeod, Kwok Ho Lam et al.
4 citations
NDT & E International
Ultrasonics and Acoustic Wave Propagation
1.08
article

Application of Golay-based total focusing method using a high-frequency, lead-free, flexible ultrasonic array for inspection of thick non-planar industrial components

Heather Trodden, David Lines, Charles MacLeod, Kwok Ho Lam, Morteza Tabatabaeipour, Ehsan Mohseni, Anthony Gachagan, D.L. Hughes, Elmergue Germano
article en
4 citations

Abstract

The compromise between axial resolution and penetration depth in ultrasound imaging poses a challenge for high-frequency ultrasonic arrays, limiting their ability to effectively inspect thick components in industrial applications. In this work, a commercial 20 MHz, 64 element, 1 mm pitch lead-free flexible linear array was characterised in terms of its performance. The array was subsequently evaluated using Golay-coded excitation techniques to enhance the signal-to-noise ratio (SNR) and operability on non-planar thick components. The SNR improvement verification results were acquired with the array deployed on a 100 mm thick flat aluminium test specimen. As expected, an increase in SNR was observed as the Golay code length increased. The imaging strategy employed a combination of Full Matrix Capture (FMC) and Total Focusing Method (TFM) to assess the performance variations between the conventional pulse excitation and Golay-coded excitation. The Golay-based TFM demonstrated superior performance compared to the conventional pulse-based TFM, with an SNR improvement of 4.95 dB when using the full array aperture to inspect the non-planar steel S355 specimen. A sub-aperture selection approach, based on the effect of the array element beam spread, offered additional SNR improvement of up to 8.2 dB. Greater imaging penetration depth was achieved, with an increase of >40 % compared to conventional pulse-based TFM. Thus, for inspection of thick non-planar industrial components using a lead-free high-frequency array, Golay-coded excitation schemes show excellent potential to enhance SNR, penetration depth and imaging quality.

NDT & E InternationalVol. 150
University of Ulster (GB), University of Strathclyde (GB), Motor Design (United Kingdom) (GB), University of Glasgow (GB)
Industry, innovation and infrastructure
Openalex Percentile: Top 26%
Ultrasonics and Acoustic Wave Propagation
1.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.