Assessment of hemodynamic parameters by PiCCO and PAC in patients treated with the Impella CP

In 28 patients supported by an Impella pump (Impella CP, Abiomed Inc.<sup>®</sup>, Danvers, MA), hemodynamic measurements by PiCCO (PULSION Medical Systems SE<sup>®</sup>, Feldkirchen, Germany) and pulmonary artery catheter (PAC or Swan-Ganz Catheter; Edwards Lifescience<sup>®</sup>, Unterschleissheim, Germany) were compared. There was a significant positive correlation of cardiac output (CO; <i>r</i> <sup>2</sup> = 0.917, <i>p</i> < 0.001), systemic vascular resistance index (SVRI; <i>r</i> <sup>2</sup> = 0.904, <i>p</i> < 0.001), stroke volume index (SI; <i>r</i> <sup>2</sup> = 0.909, <i>p</i> < 0.001) and left ventricular work index (LCWI; <i>r</i> <sup>2</sup> = 0.689, <i>p</i> < 0.001) in PiCCO and PAC measurements under Impella CP support. We conclude, that in patients with left-ventricular Impella support, hemodynamics may be assessentd by PiCCO or PAC.

Authors

Institutions

Publication Details

Journal
Journal of the Intensive Care Society
Published
2024-11-25
DOI
https://doi.org/10.1177/17511437241300909
Citations
1
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of hemodynamic parameters by PiCCO and PAC in patients treated with the Impella CP

Dirk Weismann, Björn Lengenfelder, Stefan Frantz, Dominik Schmitt et al.
1 citations
Journal of the Intensive Care Society
Hemodynamic Monitoring and Therapy
0.57
article

Assessment of hemodynamic parameters by PiCCO and PAC in patients treated with the Impella CP

Dirk Weismann, Björn Lengenfelder, Stefan Frantz, Dominik Schmitt, Daniel Patschan, Georg Ertl, Benjamin Sasko, Martin Wagner, Oliver Ritter, Andreas Schneider
article en
1 citations

Abstract

In 28 patients supported by an Impella pump (Impella CP, Abiomed Inc.<sup>®</sup>, Danvers, MA), hemodynamic measurements by PiCCO (PULSION Medical Systems SE<sup>®</sup>, Feldkirchen, Germany) and pulmonary artery catheter (PAC or Swan-Ganz Catheter; Edwards Lifescience<sup>®</sup>, Unterschleissheim, Germany) were compared. There was a significant positive correlation of cardiac output (CO; <i>r</i> <sup>2</sup> = 0.917, <i>p</i> < 0.001), systemic vascular resistance index (SVRI; <i>r</i> <sup>2</sup> = 0.904, <i>p</i> < 0.001), stroke volume index (SI; <i>r</i> <sup>2</sup> = 0.909, <i>p</i> < 0.001) and left ventricular work index (LCWI; <i>r</i> <sup>2</sup> = 0.689, <i>p</i> < 0.001) in PiCCO and PAC measurements under Impella CP support. We conclude, that in patients with left-ventricular Impella support, hemodynamics may be assessentd by PiCCO or PAC.

Journal of the Intensive Care SocietyVol. 26(1)
University of Würzburg (DE), Comprehensive Cancer Center Mainfranken (DE), Marienhospital Bottrop (DE), Universitätsklinikum Würzburg (DE), Medizinische Hochschule Brandenburg Theodor Fontane (DE), Brandenburg University of Technology Cottbus-Senftenberg (DE), University of Duisburg-Essen (DE), Bayer (Germany) (DE)
Responsible consumption and production
Openalex Percentile: Top 27%
Hemodynamic Monitoring and Therapy
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of hemodynamic parameters by PiCCO and PAC in patients treated with the Impella CP — Dirk Weismann, Björn Lengenfelder, et al. · Journal of the Intensive Care Society (2024) | TGRS Research Map | TGRS