Radionuclide release from spent nuclear fuel in sealed glass ampoules

Radiation from spent nuclear fuel affects the redox chemistry of water in the proximity of the fuel surface. The overall effect of the radiolysis is oxidizing so that U(IV) in the spent nuclear fuel is oxidized to U(VI). The dissolution of U(VI) is relatively fast, especially when the water contains bicarbonate. Based on this, radiolytic oxidation is considered the main driving force for spent fuel dissolution and radionuclide release in a spent fuel repository environment, and many studies over the years have aimed to further our understanding of this process and how it is influenced by available redox active components in open and closed systems. Here, data from sealed glass ampoules in which spent fuel is leached for one and five years, are compared with published data from a previous similar experiment. With regards to evolution of radiolytic gases, the results are comparable to the results from the previous experiments: a steady state with regards to oxygen and hydrogen composition is observed. An unexpected observation is that some ampoules with old, pre-oxidized fragments produced less radiolytic gases. These older fragments release a larger fraction of the radionuclide inventory of the samples, yielding concentrations that are on the same level as previously published data. The data from the old fragments presented here are affected by the pre-oxidation and prolonged washing procedure, which confounds the interpretation of those data. New, recently prepared fragments yield data that are easier to interpret. The radionuclide concentrations in the ampoules with new fragments are much lower; uranium concentrations of ca 5E-6 M after one year, and ca 3E-5 M after five years. Using the calculated radionuclide inventory in the fuel samples, an apparent radionuclide release rate in these initially anoxic systems, based on U release, is ca 3E-5 per year. • Radiolysis from spent nuclear fuel under initially anoxic conditions cause oxidative dissolution. • Gas evolution in sealed ampoules indicate concentration plateaus for hydrogen and oxygen. • Radionuclide release is affected by sample pre-oxidation. • Fresh spent fuel samples show slow radionuclide release over a five year timespan.

Authors

Institutions

Publication Details

Journal
Applied Geochemistry
Published
2024-11-25
DOI
https://doi.org/10.1016/j.apgeochem.2024.106234
Citations
1
Primary Topic
Nuclear Materials and Properties
Type
article
Field-Weighted Citation Impact
0.12

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radionuclide release from spent nuclear fuel in sealed glass ampoules

Kastriot Spahiu, Evins Lena Z, Askeljung Charlotta, Barreiro Fidalgo Alexandre et al.
1 citations
Applied Geochemistry
Nuclear Materials and Properties
0.12
article

Radionuclide release from spent nuclear fuel in sealed glass ampoules

Kastriot Spahiu, Evins Lena Z, Askeljung Charlotta, Barreiro Fidalgo Alexandre, Puranen Anders, Roth Olivia
article en
1 citations

Abstract

Radiation from spent nuclear fuel affects the redox chemistry of water in the proximity of the fuel surface. The overall effect of the radiolysis is oxidizing so that U(IV) in the spent nuclear fuel is oxidized to U(VI). The dissolution of U(VI) is relatively fast, especially when the water contains bicarbonate. Based on this, radiolytic oxidation is considered the main driving force for spent fuel dissolution and radionuclide release in a spent fuel repository environment, and many studies over the years have aimed to further our understanding of this process and how it is influenced by available redox active components in open and closed systems. Here, data from sealed glass ampoules in which spent fuel is leached for one and five years, are compared with published data from a previous similar experiment. With regards to evolution of radiolytic gases, the results are comparable to the results from the previous experiments: a steady state with regards to oxygen and hydrogen composition is observed. An unexpected observation is that some ampoules with old, pre-oxidized fragments produced less radiolytic gases. These older fragments release a larger fraction of the radionuclide inventory of the samples, yielding concentrations that are on the same level as previously published data. The data from the old fragments presented here are affected by the pre-oxidation and prolonged washing procedure, which confounds the interpretation of those data. New, recently prepared fragments yield data that are easier to interpret. The radionuclide concentrations in the ampoules with new fragments are much lower; uranium concentrations of ca 5E-6 M after one year, and ca 3E-5 M after five years. Using the calculated radionuclide inventory in the fuel samples, an apparent radionuclide release rate in these initially anoxic systems, based on U release, is ca 3E-5 per year. • Radiolysis from spent nuclear fuel under initially anoxic conditions cause oxidative dissolution. • Gas evolution in sealed ampoules indicate concentration plateaus for hydrogen and oxygen. • Radionuclide release is affected by sample pre-oxidation. • Fresh spent fuel samples show slow radionuclide release over a five year timespan.

Applied GeochemistryVol. 178
Studsvik (Sweden) (SE), Swedish Nuclear Fuel and Waste Management (Sweden) (SE)
Svensk Kärnbränslehantering
Affordable and clean energy
Openalex Percentile: Top 58%
Nuclear Materials and Properties
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.