A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals

In recent years, the detection of nitrosamine precursors has become an important issue for regulatory authorities such as the European Medicines Agency (EMA) and the Food and Drug Administration (FDA). The present study provides a pre-column derivatization method for the analysis of dimethylamine (DMA) and diethylamine (DEA) in pharmaceutical products using HPLC and a fluorescence detector. Appropriate chromatographic parameters, including mobile phase composition (organic solvent, buffer, pH), elution type, flow rate, temperature, and λexcitation/emission, were investigated. Analysis was performed at λ<sub>excitation</sub> = 450 nm and λ<sub>emission</sub> = 540 nm on a C<sub>18</sub> column (at 40 °C) using gradient elution as a mobile phase with Eluent A: Phosphoric Acid Buffer (20 mM, pH = 2.8) and Eluent B: methanol, with a flow of 0.8 mL/min. The method was validated according to ICH specifications in terms of linearity (0.5-10 ng/mL for DMA and 5-100 ng/mL for DEA), specificity, and robustness, as well as repeatability, intermediate precision (%RSD < 2.9), and accuracy (% recovery 98.2-102.0%). The derivatization process was optimized using the "Crossed D-Optimal" experimental design procedure, where one mixture component was cross-correlated with two factors. The stability of the samples was studied over a period of one month. To process the samples (pharmaceuticals), various purification techniques were tried using solid/liquid or liquid/liquid extraction with dichloromethane. Finally, a straightforward solid-phase extraction (SPE, C<sub>18</sub>) method was chosen prior to derivatization. The method was successfully applied, since the extraction recoveries were >81.6% for DMA (0.5 ppm) and >81.1% for DEA (5 ppm). Based on the results obtained and the available literature, the scientific community seeks, by proposing flexible analytical methods, to delimit the problem of nitrosamines.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2024-11-23
DOI
https://doi.org/10.3390/molecules29235535
Citations
3
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals

Sofia Almpani, Catherine K. Markopoulou, Georgios Kamaris, Maria Tsami et al.
3 citations
Molecules
Analytical chemistry methods development
0.71
article

A Pre-Column Derivatization Method for the HPLC-FLD Determination of Dimethyl and Diethyl Amine in Pharmaceuticals

Sofia Almpani, Catherine K. Markopoulou, Georgios Kamaris, Maria Tsami, Georgiana-Roxana Lotca
article en
3 citations

Abstract

In recent years, the detection of nitrosamine precursors has become an important issue for regulatory authorities such as the European Medicines Agency (EMA) and the Food and Drug Administration (FDA). The present study provides a pre-column derivatization method for the analysis of dimethylamine (DMA) and diethylamine (DEA) in pharmaceutical products using HPLC and a fluorescence detector. Appropriate chromatographic parameters, including mobile phase composition (organic solvent, buffer, pH), elution type, flow rate, temperature, and λexcitation/emission, were investigated. Analysis was performed at λ<sub>excitation</sub> = 450 nm and λ<sub>emission</sub> = 540 nm on a C<sub>18</sub> column (at 40 °C) using gradient elution as a mobile phase with Eluent A: Phosphoric Acid Buffer (20 mM, pH = 2.8) and Eluent B: methanol, with a flow of 0.8 mL/min. The method was validated according to ICH specifications in terms of linearity (0.5-10 ng/mL for DMA and 5-100 ng/mL for DEA), specificity, and robustness, as well as repeatability, intermediate precision (%RSD < 2.9), and accuracy (% recovery 98.2-102.0%). The derivatization process was optimized using the "Crossed D-Optimal" experimental design procedure, where one mixture component was cross-correlated with two factors. The stability of the samples was studied over a period of one month. To process the samples (pharmaceuticals), various purification techniques were tried using solid/liquid or liquid/liquid extraction with dichloromethane. Finally, a straightforward solid-phase extraction (SPE, C<sub>18</sub>) method was chosen prior to derivatization. The method was successfully applied, since the extraction recoveries were >81.6% for DMA (0.5 ppm) and >81.1% for DEA (5 ppm). Based on the results obtained and the available literature, the scientific community seeks, by proposing flexible analytical methods, to delimit the problem of nitrosamines.

MoleculesVol. 29(23)
Aristotle University of Thessaloniki (GR)
Openalex Percentile: Top 33%
Analytical chemistry methods development
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.