Refined speckle contrast estimation in OCT based on compensation of scattering-related distortions of speckle pattern parameters

Abstract Speckle contrast (SC) parameters in optical coherence tomography (OCT) scans are formed by the interplay of several factors—local level of optical wave backscattering by the material inhomogeneities, parameters of spatial distribution of the latter and the degree of cumulative optical wave attenuation during its fourth-and-back propagation. For the optical wavelengths used in OCT, this attenuation is usually dominated by the influence of scattering in the visualized turbid tissues rather than by absorption. For sufficiently high concentrations of scatterers (at least a few scatterers in the coherence volume) characterized by comparable scattering strengths and a fairly homogeneous distribution in space, the interference of locally scattered waves should be characterized by a Rayleigh distribution of speckle amplitudes, for which the local SC tends to 0.52. Equivalently, in terms of speckle intensities, the local SC tends to unity. Local spatial inhomogeneities or strongly uneven scattering strengths lead to the appearance of increased values of SC, which may serve as a diagnostic feature of some tissue components in OCT images. At the same time, in comparison to surface speckles formed by coherent-light scattering from rough surfaces, OCT-beam attenuation during its fourth-and-back propagation may introduce intensity inhomogeneities in OCT scans even for homogeneous tissue areas. This effect results in artefactual distortion of the visible SC in comparison with the above-mentioned expected value. Moreover, the presence of individual strong scatterers may additionally non-locally distort SC values due to the appearance of elongated shadows below such scatterers, which causes lateral inhomogeneities in OCT scans. Here, we propose a refined SC parameter, which is cleaned from distorting scattering-related effects in both axial and lateral directions. Depth-resolved estimation of the optical attenuation coefficient is used to restore attenuation-free OCT scans, for which the refined SC is estimated. The efficiency of the proposed approach is demonstrated using both digital OCT phantoms with highly controlled properties and experimental OCT data.

Authors

Institutions

Publication Details

Journal
Laser Physics Letters
Published
2024-11-25
DOI
https://doi.org/10.1088/1612-202x/ad9149
Citations
5
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Refined speckle contrast estimation in OCT based on compensation of scattering-related distortions of speckle pattern parameters

I. Alex Vitkin, Alexander L. Matveyev, Maher Assaad, Vladimir Y. Zaitsev et al.
5 citations
Laser Physics Letters
Optical Coherence Tomography Applications
0.92
article

Refined speckle contrast estimation in OCT based on compensation of scattering-related distortions of speckle pattern parameters

I. Alex Vitkin, Alexander L. Matveyev, Maher Assaad, Vladimir Y. Zaitsev, Lev A. Matveev, Alexander A. Sovetsky
article en
5 citations

Abstract

Abstract Speckle contrast (SC) parameters in optical coherence tomography (OCT) scans are formed by the interplay of several factors—local level of optical wave backscattering by the material inhomogeneities, parameters of spatial distribution of the latter and the degree of cumulative optical wave attenuation during its fourth-and-back propagation. For the optical wavelengths used in OCT, this attenuation is usually dominated by the influence of scattering in the visualized turbid tissues rather than by absorption. For sufficiently high concentrations of scatterers (at least a few scatterers in the coherence volume) characterized by comparable scattering strengths and a fairly homogeneous distribution in space, the interference of locally scattered waves should be characterized by a Rayleigh distribution of speckle amplitudes, for which the local SC tends to 0.52. Equivalently, in terms of speckle intensities, the local SC tends to unity. Local spatial inhomogeneities or strongly uneven scattering strengths lead to the appearance of increased values of SC, which may serve as a diagnostic feature of some tissue components in OCT images. At the same time, in comparison to surface speckles formed by coherent-light scattering from rough surfaces, OCT-beam attenuation during its fourth-and-back propagation may introduce intensity inhomogeneities in OCT scans even for homogeneous tissue areas. This effect results in artefactual distortion of the visible SC in comparison with the above-mentioned expected value. Moreover, the presence of individual strong scatterers may additionally non-locally distort SC values due to the appearance of elongated shadows below such scatterers, which causes lateral inhomogeneities in OCT scans. Here, we propose a refined SC parameter, which is cleaned from distorting scattering-related effects in both axial and lateral directions. Depth-resolved estimation of the optical attenuation coefficient is used to restore attenuation-free OCT scans, for which the refined SC is estimated. The efficiency of the proposed approach is demonstrated using both digital OCT phantoms with highly controlled properties and experimental OCT data.

Laser Physics LettersVol. 22(1)
Ajman University (AE), University of Toronto (CA), Princess Margaret Cancer Centre (CA), Institute of Applied Physics (RU)
Sustainable cities and communities
Openalex Percentile: Top 27%
Optical Coherence Tomography Applications
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.