Hybrid power plant in FCR-N provision: An analysis of storage sizing in connection with turbine stress reduction

This paper examines the capability of a linear time-invariant (LTI) filter to reduce the stress of turbine units in hybrid power plants providing Frequency Containment Reserve (FCR) for primary control of the power grid. The main focus is to analyze the effect of filter parametrization on the stress reduction under the dynamic performance criteria given by the Nordic FCR requirements. Analytic derivations are targeted to gain insight into the dependencies of attainable stress reduction, and storage sizing as a function of the FCR test and filter parameters. The study revealed that the filter utilizes an available storage system inefficiently, resulting in low performance in terms of turbine stress reduction and high energy usage. The obtained results are valid for any turbine and storage combination with suitable characteristics for FCR operation since the analysis focused on power behavior. • Distribution of the load between turbine and energy storage using an LTI filter. • Analysis of filter parameters on the turbine stress reduction. • Examination of the filter performance regarding storage sizing.

Authors

Institutions

Publication Details

Journal
Electric Power Systems Research
Published
2024-11-25
DOI
https://doi.org/10.1016/j.epsr.2024.111243
Citations
2
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid power plant in FCR-N provision: An analysis of storage sizing in connection with turbine stress reduction

Enso Ikonen, Joni Vasara, István Selek
2 citations
Electric Power Systems Research
Hybrid Renewable Energy Systems
0.34
article

Hybrid power plant in FCR-N provision: An analysis of storage sizing in connection with turbine stress reduction

Enso Ikonen, Joni Vasara, István Selek
article en
2 citations

Abstract

This paper examines the capability of a linear time-invariant (LTI) filter to reduce the stress of turbine units in hybrid power plants providing Frequency Containment Reserve (FCR) for primary control of the power grid. The main focus is to analyze the effect of filter parametrization on the stress reduction under the dynamic performance criteria given by the Nordic FCR requirements. Analytic derivations are targeted to gain insight into the dependencies of attainable stress reduction, and storage sizing as a function of the FCR test and filter parameters. The study revealed that the filter utilizes an available storage system inefficiently, resulting in low performance in terms of turbine stress reduction and high energy usage. The obtained results are valid for any turbine and storage combination with suitable characteristics for FCR operation since the analysis focused on power behavior. • Distribution of the load between turbine and energy storage using an LTI filter. • Analysis of filter parameters on the turbine stress reduction. • Examination of the filter performance regarding storage sizing.

Electric Power Systems ResearchVol. 239
University of Oulu (FI)
Affordable and clean energy
Openalex Percentile: Top 33%
Hybrid Renewable Energy Systems
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.