Study on the Resonance Characteristics and Active Damping Suppression Strategies of Multi-Inverter Grid-Connected Systems Under Weak Grid Conditions

When a multi-inverter grid-connected system is influenced by the parasitic parameters of LCL-type inverters and the impedance of the connected system’s lines, its resonance characteristics become more complex and difficult to predict. For LCL-type multi-inverter grid-connected systems, a mathematical model that considers the effects of parasitic parameters and line impedance has been established, leading to the derivation of the system’s Norton equivalent circuit and a general expression for the inverter output current. The resonance characteristics of multi-inverter grid-connected systems composed of inverters with the same and different parameters were analyzed under the influence of parasitic parameters and line impedance. To suppress the resonance in multi-inverter grid-connected systems and address the issue of traditional PI control not meeting grid requirements for LCL-type grid-connected inverters, a strategy combining superhelical sliding mode control with active damping was adopted. To verify the practical performance of the adopted resonance suppression strategy in complex environments, a grid-connected system model containing two LCL-type inverters was constructed using the MATLAB/Simulink software platform, followed by simulation analysis. The simulation results strongly confirm the feasibility and effectiveness of the adopted resonance suppression strategy, considering the effects of parasitic parameters and line impedance. This strategy demonstrates significant suppression effects in addressing resonance issues caused by parasitic parameters and line impedance, effectively enhancing the quality of grid-connected electrical energy.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-11-23
DOI
https://doi.org/10.3390/en17235889
Citations
7
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
2.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Resonance Characteristics and Active Damping Suppression Strategies of Multi-Inverter Grid-Connected Systems Under Weak Grid Conditions

Yunhao Jiang, Zishuo Cai, Tianhao Hou
7 citations
Energies
Microgrid Control and Optimization
2.30
article

Study on the Resonance Characteristics and Active Damping Suppression Strategies of Multi-Inverter Grid-Connected Systems Under Weak Grid Conditions

Yunhao Jiang, Zishuo Cai, Tianhao Hou
article en
7 citations

Abstract

When a multi-inverter grid-connected system is influenced by the parasitic parameters of LCL-type inverters and the impedance of the connected system’s lines, its resonance characteristics become more complex and difficult to predict. For LCL-type multi-inverter grid-connected systems, a mathematical model that considers the effects of parasitic parameters and line impedance has been established, leading to the derivation of the system’s Norton equivalent circuit and a general expression for the inverter output current. The resonance characteristics of multi-inverter grid-connected systems composed of inverters with the same and different parameters were analyzed under the influence of parasitic parameters and line impedance. To suppress the resonance in multi-inverter grid-connected systems and address the issue of traditional PI control not meeting grid requirements for LCL-type grid-connected inverters, a strategy combining superhelical sliding mode control with active damping was adopted. To verify the practical performance of the adopted resonance suppression strategy in complex environments, a grid-connected system model containing two LCL-type inverters was constructed using the MATLAB/Simulink software platform, followed by simulation analysis. The simulation results strongly confirm the feasibility and effectiveness of the adopted resonance suppression strategy, considering the effects of parasitic parameters and line impedance. This strategy demonstrates significant suppression effects in addressing resonance issues caused by parasitic parameters and line impedance, effectively enhancing the quality of grid-connected electrical energy.

EnergiesVol. 17(23)
Hubei University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 11%
Microgrid Control and Optimization
2.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.