The Development of an Electron Pulse Dilation Photomultiplier Tube Diagnostic Instrument

A new pulse-dilated photomultiplier tube (PD-PMT) with sub-20 ps temporal resolution and associated drivers have been developed for use detection and signal amplification in the inertial confinement fusion (ICF) community. The PD-PMT is coupled to a transmission line output in order to provide a continuous time history of the input signal. Electron pulse dilation provides high-speed detection capabilities by converting incoming signals into a free-electron cloud and manipulating the electron signal with electric and magnetic fields. This velocity dispersion is translated into temporal separation after the electrons transit into a drift space. The free electrons are then detected by using conventional time-resolved methods and the effective temporal resolution is improved about 12 times. In order to accurately obtain the actual device input signal, we experimentally investigated the relationship between microchannel plate (MCP) gain and electron energy during the first collision. We report the measurements with the PD-PMT, and the error source of the amplitude of the compressed signal is analyzed, which provides a reference for subsequent accurate construction.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-11-24
DOI
https://doi.org/10.3390/s24237497
Citations
2
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
1.32
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Development of an Electron Pulse Dilation Photomultiplier Tube Diagnostic Instrument

Rongyan Zhou, Ping Chen, Wenyong Fu, Ling Li et al.
2 citations
Sensors
Laser-Plasma Interactions and Diagnostics
1.32
article

The Development of an Electron Pulse Dilation Photomultiplier Tube Diagnostic Instrument

Rongyan Zhou, Ping Chen, Wenyong Fu, Ling Li, Chenman Hu
article en
2 citations

Abstract

A new pulse-dilated photomultiplier tube (PD-PMT) with sub-20 ps temporal resolution and associated drivers have been developed for use detection and signal amplification in the inertial confinement fusion (ICF) community. The PD-PMT is coupled to a transmission line output in order to provide a continuous time history of the input signal. Electron pulse dilation provides high-speed detection capabilities by converting incoming signals into a free-electron cloud and manipulating the electron signal with electric and magnetic fields. This velocity dispersion is translated into temporal separation after the electrons transit into a drift space. The free electrons are then detected by using conventional time-resolved methods and the effective temporal resolution is improved about 12 times. In order to accurately obtain the actual device input signal, we experimentally investigated the relationship between microchannel plate (MCP) gain and electron energy during the first collision. We report the measurements with the PD-PMT, and the error source of the amplitude of the compressed signal is analyzed, which provides a reference for subsequent accurate construction.

SensorsVol. 24(23)
Hengshui University (CN), Nanyang Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
Laser-Plasma Interactions and Diagnostics
1.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Development of an Electron Pulse Dilation Photomultiplier Tube Diagnostic Instrument — Rongyan Zhou, Ping Chen, et al. · Sensors (2024) | TGRS Research Map | TGRS