Transient Stability-Based Fast Power System Contingency Screening and Ranking

Today’s power systems are operated closer to their stability limits due to the continuously growing load demands, interface to open markets, and integration of more renewable energies. In order to provide operators with clear insight on the current system situation, near real-time power systems dynamic security assessment tools are required. One of the core elements of near real-time dynamic security assessment tools is contingency screening and ranking. Most of the commercially available tools screen and rank contingencies by using the traditional numerical integration or Transient Energy Functions (TEFs) or hybrid methods. The traditional numerical integration method is accurate but computationally intensive and has a slow assessment speed which makes it difficult to identify any insecure contingency before it happens. Despite the TEF method of transient stability analysis being relatively fast, it develops less accurate results due to models simplification and assumptions. This paper introduces transient stability based on fast and robust contingency screening and ranking using an Adaptive step-size Differential Transformation (AsDTM) method. Based on the most current snapshot from Supervisory Control and Data Accusation (SCADA) data, the proposed method triggers AsDTM-based transient stability simulation for each credible contingency and evaluates Transient Stability Indices (TSI) as the normalized weighted sum of squares of errors derived from state variables and complex bus voltages at every simulation time step. Finally, contingencies are ranked based on these TSI and the worst contingency is identified for the next detail assessment. The method is tested on IEEE 9 bus and 39 bus test systems. Test results reveal that the proposed method is faster, robust, and can be used in near real-time dynamic security assessment sessions.

Authors

Institutions

Publication Details

Journal
Electricity
Published
2024-11-25
DOI
https://doi.org/10.3390/electricity5040048
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Stability-Based Fast Power System Contingency Screening and Ranking

Fekadu Shewarega, Teshome Lindi Kumissa
Electricity
Power System Optimization and Stability
article

Transient Stability-Based Fast Power System Contingency Screening and Ranking

Fekadu Shewarega, Teshome Lindi Kumissa
article en

Abstract

Today’s power systems are operated closer to their stability limits due to the continuously growing load demands, interface to open markets, and integration of more renewable energies. In order to provide operators with clear insight on the current system situation, near real-time power systems dynamic security assessment tools are required. One of the core elements of near real-time dynamic security assessment tools is contingency screening and ranking. Most of the commercially available tools screen and rank contingencies by using the traditional numerical integration or Transient Energy Functions (TEFs) or hybrid methods. The traditional numerical integration method is accurate but computationally intensive and has a slow assessment speed which makes it difficult to identify any insecure contingency before it happens. Despite the TEF method of transient stability analysis being relatively fast, it develops less accurate results due to models simplification and assumptions. This paper introduces transient stability based on fast and robust contingency screening and ranking using an Adaptive step-size Differential Transformation (AsDTM) method. Based on the most current snapshot from Supervisory Control and Data Accusation (SCADA) data, the proposed method triggers AsDTM-based transient stability simulation for each credible contingency and evaluates Transient Stability Indices (TSI) as the normalized weighted sum of squares of errors derived from state variables and complex bus voltages at every simulation time step. Finally, contingencies are ranked based on these TSI and the worst contingency is identified for the next detail assessment. The method is tested on IEEE 9 bus and 39 bus test systems. Test results reveal that the proposed method is faster, robust, and can be used in near real-time dynamic security assessment sessions.

ElectricityVol. 5(4)
Hawassa University (ET), University of Duisburg-Essen (DE)
Affordable and clean energy
Openalex Percentile: Top 81%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.