Online Monitoring for the Safety of Insulation of Inverter-Fed Equipment Under Varying Working Condition

The online condition method for the safety of insulation can give prognosis for potential failure in inverter-fed equipment such as motors, which can avoid the huge losses caused by the unexpected failure. In the existing methods, the equivalent impedance of the stator winding is estimated in frequency domain by measuring the terminal voltages and leakage current. Because the output voltage of the inverter has many harmonics, the frequency resolution of the monitoring method should be as high as 1~10 Hz to distinguish different harmonics. For the traditional method such as FFT (Fast Fourier Transform), the window length should be very long. If the fundamental frequency of the inverter-fed machine changes in the window in varying work condition, the existing method cannot estimate the impedance parameters accurately. Therefore, a sliding window matrix pencil method is proposed to solve this problem. The online experimental results prove that it can estimate the groundwall and phase-to-phase insulation parameters accurately in varying work condition.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/scems63294.2024.10756439
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Online Monitoring for the Safety of Insulation of Inverter-Fed Equipment Under Varying Working Condition

Pinjia Zhang, Dayong Zheng, Guodong Li, Wenqing Cui et al.
Engineering Diagnostics and Reliability
article

Online Monitoring for the Safety of Insulation of Inverter-Fed Equipment Under Varying Working Condition

Pinjia Zhang, Dayong Zheng, Guodong Li, Wenqing Cui, Bin Liu
article en

Abstract

The online condition method for the safety of insulation can give prognosis for potential failure in inverter-fed equipment such as motors, which can avoid the huge losses caused by the unexpected failure. In the existing methods, the equivalent impedance of the stator winding is estimated in frequency domain by measuring the terminal voltages and leakage current. Because the output voltage of the inverter has many harmonics, the frequency resolution of the monitoring method should be as high as 1~10 Hz to distinguish different harmonics. For the traditional method such as FFT (Fast Fourier Transform), the window length should be very long. If the fundamental frequency of the inverter-fed machine changes in the window in varying work condition, the existing method cannot estimate the impedance parameters accurately. Therefore, a sliding window matrix pencil method is proposed to solve this problem. The online experimental results prove that it can estimate the groundwall and phase-to-phase insulation parameters accurately in varying work condition.

Tianjin Research Institute of Electric Science (China) (CN), Tsinghua University (CN)
State Grid Corporation of China
Affordable and clean energy
Openalex Percentile: Top 77%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.