Cryptophane A-Based Methane Sensing in the Aqueous and Gas Phase

Methane is a crucial environmental parameter. However, the range for dissolved methane sensors must be expanded, as it lacks small, submersible sensors with sub-ppm resolution. In 2008, Boulart reported the development of a promising prototype. The sensor based on surface plasmon resonance (SPR) measurements of a polymer membrane doped with Cryptophane A (CryptA). Unfortunately, the work on this prototype was discontinued in 2013. In this study, an aqueous and gas-phase methane sensor was constructed with the objective of reproducing and enhancing the results reported by Boulart. However, as with other approaches based on CryptA, a sub-ppm resolution was not achieved. The crucial difference of Boulart's approach lies within an unexplainable high methane sensitivity of their polymer membrane.

Authors

Institutions

Publication Details

Published
2024-09-23
DOI
https://doi.org/10.1109/oceans55160.2024.10754500
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cryptophane A-Based Methane Sensing in the Aqueous and Gas Phase

Arne Estelmann, Ralf D. Prien
1 links
Gas Sensing Nanomaterials and Sensors
article

Cryptophane A-Based Methane Sensing in the Aqueous and Gas Phase

Arne Estelmann, Ralf D. Prien
article en

Abstract

Methane is a crucial environmental parameter. However, the range for dissolved methane sensors must be expanded, as it lacks small, submersible sensors with sub-ppm resolution. In 2008, Boulart reported the development of a promising prototype. The sensor based on surface plasmon resonance (SPR) measurements of a polymer membrane doped with Cryptophane A (CryptA). Unfortunately, the work on this prototype was discontinued in 2013. In this study, an aqueous and gas-phase methane sensor was constructed with the objective of reproducing and enhancing the results reported by Boulart. However, as with other approaches based on CryptA, a sub-ppm resolution was not achieved. The crucial difference of Boulart's approach lies within an unexplainable high methane sensitivity of their polymer membrane.

Leibniz Institute for Baltic Sea Research Warnemünde (DE)
Clean water and sanitation
Openalex Percentile: Top 81%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.