Deep Learning for High Speed Optical Coherence Elastography With a Fiber Scanning Endoscope

Tissue stiffness is related to soft tissue pathologies and can be assessed through palpation or via clinical imaging systems, e.g., ultrasound or magnetic resonance imaging. Typically, the image based approaches are not suitable during interventions, particularly for minimally invasive surgery. To this end, we present a miniaturized fiber scanning endoscope for fast and localized elastography. Moreover, we propose a deep learning based signal processing pipeline to account for the intricate data and the need for real-time estimates. Our elasticity estimation approach is based on imaging complex and diffuse wave fields that encompass multiple wave frequencies and propagate in various directions. We optimize the probe design to enable different scan patterns. To maximize temporal sampling while maintaining three-dimensional information we define a scan pattern in a conical shape with a temporal frequency of 5.05kHz. To efficiently process the image sequences of complex wave fields we consider a spatio-temporal deep learning network. We train the network in an end-to-end fashion on measurements from phantoms representing multiple elasticities. The network is used to obtain localized and robust elasticity estimates, allowing to create elasticity maps in real-time. For 2D scanning, our approach results in a mean absolute error of 6.31(576)kPa compared to 11.33(1278)kPa for conventional phase tracking. For scanning without estimating the wave direction, the novel 3D method reduces the error to 4.48(363)kPa compared to 19.75(2182)kPa for the conventional 2D method. Finally, we demonstrate feasibility of elasticity estimates in ex-vivo porcine tissue.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2024-11-25
DOI
https://doi.org/10.1109/tmi.2024.3505676
Citations
6
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning for High Speed Optical Coherence Elastography With a Fiber Scanning Endoscope

Tim Eixmann, Maximilian Neidhardt, Gereon Hüttmann, Sarah Latus et al.
6 citations
IEEE Transactions on Medical Imaging
Optical Coherence Tomography Applications
1.11
article

Deep Learning for High Speed Optical Coherence Elastography With a Fiber Scanning Endoscope

Tim Eixmann, Maximilian Neidhardt, Gereon Hüttmann, Sarah Latus, Alexander Schlaefer
article en
6 citations

Abstract

Tissue stiffness is related to soft tissue pathologies and can be assessed through palpation or via clinical imaging systems, e.g., ultrasound or magnetic resonance imaging. Typically, the image based approaches are not suitable during interventions, particularly for minimally invasive surgery. To this end, we present a miniaturized fiber scanning endoscope for fast and localized elastography. Moreover, we propose a deep learning based signal processing pipeline to account for the intricate data and the need for real-time estimates. Our elasticity estimation approach is based on imaging complex and diffuse wave fields that encompass multiple wave frequencies and propagate in various directions. We optimize the probe design to enable different scan patterns. To maximize temporal sampling while maintaining three-dimensional information we define a scan pattern in a conical shape with a temporal frequency of 5.05kHz. To efficiently process the image sequences of complex wave fields we consider a spatio-temporal deep learning network. We train the network in an end-to-end fashion on measurements from phantoms representing multiple elasticities. The network is used to obtain localized and robust elasticity estimates, allowing to create elasticity maps in real-time. For 2D scanning, our approach results in a mean absolute error of 6.31(576)kPa compared to 11.33(1278)kPa for conventional phase tracking. For scanning without estimating the wave direction, the novel 3D method reduces the error to 4.48(363)kPa compared to 19.75(2182)kPa for the conventional 2D method. Finally, we demonstrate feasibility of elasticity estimates in ex-vivo porcine tissue.

IEEE Transactions on Medical ImagingVol. 44(3)
Universität Hamburg (DE), Hamburg University of Technology (DE)
Deutsche Forschungsgemeinschaft
Affordable and clean energy
Openalex Percentile: Top 24%
Optical Coherence Tomography Applications
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.