Gold/Cerium(IV) Oxide-Modified Flexible Electrodes for Enzymatic Detection of Triglyceride

Triglyceride (TG) testing aids in determining the likelihood of heart disease development. An elevated TG level increases the risk of heart attack and stroke by causing atherosclerosis. Point-of-care TG detection not only identifies these risks earlier but also enables user-friendly, cost-effective onsite usage. Thus, in this work, for the detection of TG, an electrochemical biosensor has been developed with a primary focus on portability and affordability. The sensor consists of an electrochemical cell fabricated with screen-printed carbon electrodes printed on commercially available overhead projector sheets. The detection approach is enzymatic, with lipase acting as the primary detector, immobilized on an Au/CeO<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>-modified working electrode. The current generated during the enzymatic reaction between the immobilized lipase and TG sample is proportional to the sample concentration. The electrochemical technique, cyclic voltammetry (CV), is used to quantify the amount of TG. The sensor is fabricated and tested with a solution of glyceryl tributyrate at a concentration range of 0.2 to 10 mM without the need for sample pretreatment. A portable potentiostat is utilized to perform the electrochemical characterization of the fabricated device. The calculated limit of detection and limit of quantification of TG are 0.25 and 0.76 mM, respectively. The proposed design is compact, easy to fabricate, and highly portable, showing great potential for continuous point-of-care monitoring of human TG levels.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2024-11-25
DOI
https://doi.org/10.1109/lsens.2024.3506160
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gold/Cerium(IV) Oxide-Modified Flexible Electrodes for Enzymatic Detection of Triglyceride

Khairunnisa Amreen, Sanket Goel, R. N. Ponnalagu, Parvathy Nair et al.
3 citations
IEEE Sensors Letters
Electrochemical sensors and biosensors
0.63
article

Gold/Cerium(IV) Oxide-Modified Flexible Electrodes for Enzymatic Detection of Triglyceride

Khairunnisa Amreen, Sanket Goel, R. N. Ponnalagu, Parvathy Nair, Varun Vikram Santurkar
article en
3 citations

Abstract

Triglyceride (TG) testing aids in determining the likelihood of heart disease development. An elevated TG level increases the risk of heart attack and stroke by causing atherosclerosis. Point-of-care TG detection not only identifies these risks earlier but also enables user-friendly, cost-effective onsite usage. Thus, in this work, for the detection of TG, an electrochemical biosensor has been developed with a primary focus on portability and affordability. The sensor consists of an electrochemical cell fabricated with screen-printed carbon electrodes printed on commercially available overhead projector sheets. The detection approach is enzymatic, with lipase acting as the primary detector, immobilized on an Au/CeO<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>-modified working electrode. The current generated during the enzymatic reaction between the immobilized lipase and TG sample is proportional to the sample concentration. The electrochemical technique, cyclic voltammetry (CV), is used to quantify the amount of TG. The sensor is fabricated and tested with a solution of glyceryl tributyrate at a concentration range of 0.2 to 10 mM without the need for sample pretreatment. A portable potentiostat is utilized to perform the electrochemical characterization of the fabricated device. The calculated limit of detection and limit of quantification of TG are 0.25 and 0.76 mM, respectively. The proposed design is compact, easy to fabricate, and highly portable, showing great potential for continuous point-of-care monitoring of human TG levels.

IEEE Sensors LettersVol. 8(12)
Birla Institute of Technology and Science, Pilani (IN)
Openalex Percentile: Top 30%
Electrochemical sensors and biosensors
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Gold/Cerium(IV) Oxide-Modified Flexible Electrodes for Enzymatic Detection of Triglyceride — Khairunnisa Amreen, Sanket Goel, et al. · IEEE Sensors Letters (2024) | TGRS Research Map | TGRS