Achieving Dexterous Bidirectional Interaction in Uncertain Conditions for Medical Robotics

Medical robotics can help improve the reach of healthcare services. A challenge for medical robots is their complex physical interaction. This work evaluates a recently introduced control architecture based on Fractal Impedance Control (FIC) in medical applications. The deployed FIC architecture is robust to delay between the master and the replica robots and can switch online between an admittance and impedance behavior. Our experiments analyze three scenarios: teleoperated surgery, rehabilitation, and remote ultrasound scan. The experiments did not require any adjustment of the robot tuning, which is essential in medical applications where the operators do not have an engineering background. Our results show that it is possible to teleoperate the robot to perform remote occupational therapy, operate a scalpel, and use an ultrasound scan. However, our experiments also highlighted the need for a better robot embodiment to control the system precisely in 3D dynamic tasks.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Robotics and Bionics
Published
2024-11-25
DOI
https://doi.org/10.1109/tmrb.2024.3506163
Citations
1
Primary Topic
Healthcare Technology and Patient Monitoring
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving Dexterous Bidirectional Interaction in Uncertain Conditions for Medical Robotics

Martin Asenov, Quentin Rouxel, Carlo Tiseo, Subramanian Ramamoorthy et al.
1 citations
IEEE Transactions on Medical Robotics and Bionics
Healthcare Technology and Patient Monitoring
0.57
article

Achieving Dexterous Bidirectional Interaction in Uncertain Conditions for Medical Robotics

Martin Asenov, Quentin Rouxel, Carlo Tiseo, Subramanian Ramamoorthy, Michael Mistry, Keyhan Kouhkiloui Babarahmati, Zhibin Li
article en
1 citations

Abstract

Medical robotics can help improve the reach of healthcare services. A challenge for medical robots is their complex physical interaction. This work evaluates a recently introduced control architecture based on Fractal Impedance Control (FIC) in medical applications. The deployed FIC architecture is robust to delay between the master and the replica robots and can switch online between an admittance and impedance behavior. Our experiments analyze three scenarios: teleoperated surgery, rehabilitation, and remote ultrasound scan. The experiments did not require any adjustment of the robot tuning, which is essential in medical applications where the operators do not have an engineering background. Our results show that it is possible to teleoperate the robot to perform remote occupational therapy, operate a scalpel, and use an ultrasound scan. However, our experiments also highlighted the need for a better robot embodiment to control the system precisely in 3D dynamic tasks.

IEEE Transactions on Medical Robotics and BionicsVol. 7(1)
University College London (GB), University of Edinburgh (GB)
Openalex Percentile: Top 27%
Healthcare Technology and Patient Monitoring
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Achieving Dexterous Bidirectional Interaction in Uncertain Conditions for Medical Robotics — Martin Asenov, Quentin Rouxel, et al. · IEEE Transactions on Medical Robotics and Bionics (2024) | TGRS Research Map | TGRS