SEDMamba: Enhancing Selective State Space Modelling With Bottleneck Mechanism and Fine-to-Coarse Temporal Fusion for Efficient Error Detection in Robot-Assisted Surgery

Automated detection of surgical errors can improve robotic-assisted surgery. Despite promising progress, existing methods still face challenges in capturing rich temporal context to establish long-term dependencies while maintaining computational efficiency. In this letter, we propose a novel hierarchical model named SEDMamba, which incorporates the selective state space model (SSM) into surgical error detection, facilitating efficient long sequence modelling with linear complexity. SEDMamba enhances selective SSM with a bottleneck mechanism and fine-to-coarse temporal fusion (FCTF) to detect and temporally localize surgical errors in long videos. The bottleneck mechanism compresses and restores features within their spatial dimension, thereby reducing computational complexity. FCTF utilizes multiple dilated 1D convolutional layers to merge temporal information across diverse scale ranges, accommodating errors of varying duration. Our work also contributes the first-of-its-kind, frame-level, in-vivo surgical error dataset to support error detection in real surgical cases. Specifically, we deploy the clinically validated observational clinical human reliability assessment tool (OCHRA) to annotate the errors during suturing tasks in an open-source radical prostatectomy dataset (SAR-RARP50). Experimental results demonstrate that our SEDMamba outperforms state-of-the-art methods with at least 1.82% AUC and 3.80% AP performance gains with significantly reduced computational complexity.

Authors

Institutions

Publication Details

Journal
IEEE Robotics and Automation Letters
Published
2024-11-25
DOI
https://doi.org/10.1109/lra.2024.3505818
Citations
2
Primary Topic
Reinforcement Learning in Robotics
Type
article
Field-Weighted Citation Impact
0.69

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SEDMamba: Enhancing Selective State Space Modelling With Bottleneck Mechanism and Fine-to-Coarse Temporal Fusion for Efficient Error Detection in Robot-Assisted Surgery

Matthew Boal, Evangelos B. Mazomenos, Nader Francis, Jialang Xu et al.
2 citations
IEEE Robotics and Automation Letters
Reinforcement Learning in Robotics
0.69
article

SEDMamba: Enhancing Selective State Space Modelling With Bottleneck Mechanism and Fine-to-Coarse Temporal Fusion for Efficient Error Detection in Robot-Assisted Surgery

Matthew Boal, Evangelos B. Mazomenos, Nader Francis, Jialang Xu, Danail Stoyanov, Nazir Sirajudeen
article en
2 citations

Abstract

Automated detection of surgical errors can improve robotic-assisted surgery. Despite promising progress, existing methods still face challenges in capturing rich temporal context to establish long-term dependencies while maintaining computational efficiency. In this letter, we propose a novel hierarchical model named SEDMamba, which incorporates the selective state space model (SSM) into surgical error detection, facilitating efficient long sequence modelling with linear complexity. SEDMamba enhances selective SSM with a bottleneck mechanism and fine-to-coarse temporal fusion (FCTF) to detect and temporally localize surgical errors in long videos. The bottleneck mechanism compresses and restores features within their spatial dimension, thereby reducing computational complexity. FCTF utilizes multiple dilated 1D convolutional layers to merge temporal information across diverse scale ranges, accommodating errors of varying duration. Our work also contributes the first-of-its-kind, frame-level, in-vivo surgical error dataset to support error detection in real surgical cases. Specifically, we deploy the clinically validated observational clinical human reliability assessment tool (OCHRA) to annotate the errors during suturing tasks in an open-source radical prostatectomy dataset (SAR-RARP50). Experimental results demonstrate that our SEDMamba outperforms state-of-the-art methods with at least 1.82% AUC and 3.80% AP performance gains with significantly reduced computational complexity.

IEEE Robotics and Automation LettersVol. 10(1)
Northwick Park Hospital (GB), Northwick Park Institute for Medical Research (GB), The London College (GB), St Mark's Hospital (GB), University College London (GB)
Wellcome / EPSRC Centre for Interventional and Surgical Sciences
Openalex Percentile: Top 23%
Reinforcement Learning in Robotics
0.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.