GMP-Compliant Automated Radiolabeling and Quality Controls of [<sup>68</sup>Ga]Ga-FAPI-46 for Fibroblast Activation Protein-Targeted PET Imaging in Clinical Settings

In nuclear medicine, molecular imaging of the tumor microenvironment using radiopharmaceuticals (RPs) targeting cancer-associated fibroblasts is gaining significant interest. Among these RPs, [<sup>68</sup>Ga]Ga-FAPI-46 for positron emission tomography (PET) imaging is frequently used in clinical research protocols. To ensure that the production of this RP complies with good manufacturing practices, process automation is widely adopted. In this context, an automated method for preparing [<sup>68</sup>Ga]Ga-FAPI-46 was designed using a GAIA<sup>®</sup> synthesizer. Additionally, a HPLC method was developed and validated to determine the radiochemical purity (RCP) of [<sup>68</sup>Ga]Ga-FAPI-46 and ensure product quality. The validated HPLC method showed excellent repeatability, with coefficients of variation (%CV) for RCP and retention time (t<sub>R</sub>) below 0.03 and 0.16%, respectively, across 10 measurements. The radiochemical identification of [<sup>68</sup>Ga]Ga-FAPI-46 showed comparable tr values to [<sup>nat</sup>Ga]Ga-FAPI-46 (6.65 and 6.59 min, respectively). The limits of detection (LOD) and quantification (LOQ) were 79 and 42 kBq/mL, respectively, with a linear detector response between 62.9 and 0.08 MBq/mL (R<sup>2</sup> = 0.9999). The method proved robust, tolerating minor variations in mobile phase flow rate and composition. This validated radio-HPLC method can be used routinely for the quality control of [<sup>68</sup>Ga]Ga-FAPI-46. Finally, three RP validation batches were produced using the automated method described and subjected to multiple quality controls. All three synthesis products met the expected specifications, notably regarding appearance, chemical and isotope identification, pH, sterility, stability, and radionuclidic and radiochemical purity.

Authors

Institutions

Publication Details

Journal
Chemical and Pharmaceutical Bulletin
Published
2024-11-25
DOI
https://doi.org/10.1248/cpb.c24-00531
Citations
4
Primary Topic
Peptidase Inhibition and Analysis
Type
article
Field-Weighted Citation Impact
1.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GMP-Compliant Automated Radiolabeling and Quality Controls of [68Ga]Ga-FAPI-46 for Fibroblast Activation Protein-Targeted PET Imaging in Clinical Settings

Juliette Fouillet, Léa Rubira, Cyril Fersing, Jade Torchio et al.
4 citations
Chemical and Pharmaceutical Bulletin
Peptidase Inhibition and Analysis
1.13
article

GMP-Compliant Automated Radiolabeling and Quality Controls of [68Ga]Ga-FAPI-46 for Fibroblast Activation Protein-Targeted PET Imaging in Clinical Settings

Juliette Fouillet, Léa Rubira, Cyril Fersing, Jade Torchio, Johanne Vanney
article en
4 citations

Abstract

In nuclear medicine, molecular imaging of the tumor microenvironment using radiopharmaceuticals (RPs) targeting cancer-associated fibroblasts is gaining significant interest. Among these RPs, [<sup>68</sup>Ga]Ga-FAPI-46 for positron emission tomography (PET) imaging is frequently used in clinical research protocols. To ensure that the production of this RP complies with good manufacturing practices, process automation is widely adopted. In this context, an automated method for preparing [<sup>68</sup>Ga]Ga-FAPI-46 was designed using a GAIA<sup>®</sup> synthesizer. Additionally, a HPLC method was developed and validated to determine the radiochemical purity (RCP) of [<sup>68</sup>Ga]Ga-FAPI-46 and ensure product quality. The validated HPLC method showed excellent repeatability, with coefficients of variation (%CV) for RCP and retention time (t<sub>R</sub>) below 0.03 and 0.16%, respectively, across 10 measurements. The radiochemical identification of [<sup>68</sup>Ga]Ga-FAPI-46 showed comparable tr values to [<sup>nat</sup>Ga]Ga-FAPI-46 (6.65 and 6.59 min, respectively). The limits of detection (LOD) and quantification (LOQ) were 79 and 42 kBq/mL, respectively, with a linear detector response between 62.9 and 0.08 MBq/mL (R<sup>2</sup> = 0.9999). The method proved robust, tolerating minor variations in mobile phase flow rate and composition. This validated radio-HPLC method can be used routinely for the quality control of [<sup>68</sup>Ga]Ga-FAPI-46. Finally, three RP validation batches were produced using the automated method described and subjected to multiple quality controls. All three synthesis products met the expected specifications, notably regarding appearance, chemical and isotope identification, pH, sterility, stability, and radionuclidic and radiochemical purity.

Chemical and Pharmaceutical BulletinVol. 72(11)
École Nationale Supérieure de Chimie de Montpellier (FR), Centre National de la Recherche Scientifique (FR), Université de Montpellier (FR), Cancer Institute (WIA) (IN), Institut de Recherche en Cancérologie de Montpellier (FR), Institut des Biomolécules Max Mousseron (FR)
Openalex Percentile: Top 18%
Peptidase Inhibition and Analysis
1.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.