Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localization

Abstract This paper presents a statistical forward model for a Compton imaging system, called Compton imager. This system, under development at the University of Illinois Urbana Champaign, is a variant of Compton cameras with a single type of sensors which can simultaneously act as scatterers and absorbers. This imager is convenient for imaging situations requiring a wide field of view. The proposed statistical forward model is then used to solve the inverse problem of estimating the location and energy of point-like sources from observed data. This inverse problem is formulated and solved in a Bayesian framework by using a Metropolis within Gibbs algorithm for the estimation of the location, and an expectation-maximization algorithm for the estimation of the energy. This approach leads to more accurate estimation when compared with the deterministic standard back-projection approach, with the additional benefit of uncertainty quantification in the low photon imaging setting.

Authors

Institutions

Publication Details

Journal
Inverse Problems
Published
2024-11-25
DOI
https://doi.org/10.1088/1361-6420/ad96de
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localization

Angela Di Fulvio, Cécilia Tarpau, Ming Fang, Yoann Altmann et al.
Inverse Problems
Medical Imaging Techniques and Applications
article

Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localization

Angela Di Fulvio, Cécilia Tarpau, Ming Fang, Yoann Altmann, Konstantinos C. Zygalakis, Marcelo Pereyra
article en

Abstract

Abstract This paper presents a statistical forward model for a Compton imaging system, called Compton imager. This system, under development at the University of Illinois Urbana Champaign, is a variant of Compton cameras with a single type of sensors which can simultaneously act as scatterers and absorbers. This imager is convenient for imaging situations requiring a wide field of view. The proposed statistical forward model is then used to solve the inverse problem of estimating the location and energy of point-like sources from observed data. This inverse problem is formulated and solved in a Bayesian framework by using a Metropolis within Gibbs algorithm for the estimation of the location, and an expectation-maximization algorithm for the estimation of the energy. This approach leads to more accurate estimation when compared with the deterministic standard back-projection approach, with the additional benefit of uncertainty quantification in the low photon imaging setting.

Inverse ProblemsVol. 40(12)
University of Illinois Urbana-Champaign (US), Heriot-Watt University (GB), Maxwell Institute for Mathematical Sciences (GB), University of Edinburgh (GB)
Royal Academy of Engineering, Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 65%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localization — Angela Di Fulvio, Cécilia Tarpau, et al. · Inverse Problems (2024) | TGRS Research Map | TGRS