Comparison of Implant Precision with Robots, Navigation, or Static Guides

Precise surgical positioning according to a digital plan is important for aesthetic and biologically stable dental implant restorations. This randomized controlled trial compared implant placement assisted by robotic surgery (RS), dynamic navigation (DN), or 3-dimensional printed static guide (SG). An overall 45 patients with a missing tooth in the premolar/molar region were randomly assigned to 1 of the 3 groups. Implant positional accuracy (primary outcome), early wound healing, soft tissue microcirculation, patient-reported outcome measures, and surgeon preference were measured by calibrated blind examiners. One adverse event occurred in DN and RS. In RS (<i>n</i> = 15), the global platform, apex deviation, and angular deviations (mean ± SD) were 1.1 ± 0.4 mm, 1.5 ± 0.6 mm, and 4.7° ± 2.5°, respectively. Similarly, deviations were 1.3 ± 0.6 mm, 1.9 ± 0.9 mm, and 5.5° ± 3.5° in the DN group (<i>n</i> = 14) and 1.1 ± 0.6 mm, 2.0 ± 1.2 mm, and 6.2° ± 4.0° in the SG group (<i>n</i> = 13). Significantly smaller differential deviations (mesial-distal) at the platform and apex levels were found in the RS group than the SG group (<i>P</i> < 0.05). Surgery was significantly shorter with a SG (<i>P</i> < 0.001), and this was associated with better postoperative recovery at 3 d. The surgeon assessed DN as providing easier access to reach the surgical site. No significant differences were found upon comparing soft tissue microcirculation and oxygen saturation immediately, 1 h, or 7 d after surgery. Patient-reported outcomes were comparable in the 3 groups, except that patients in the SG group reported better oral health-related quality of life 3 d after surgery. It can be concluded that RS showed near-zero 3-dimensional systematic error in implant position, while DN and SG demonstrated a centrifugal error pattern. All 3 guided approaches had uneventful wound healing and acceptable patient-reported outcomes. The 3 groups had specific cost-benefit profiles. After additional technical developments, future trials with larger sample sizes and longer follow-up periods should be performed to analyze the cost-effectiveness of different guided surgical approaches.

Authors

Institutions

Publication Details

Journal
Journal of Dental Research
Published
2024-11-25
DOI
https://doi.org/10.1177/00220345241285566
Citations
22
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
10.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Implant Precision with Robots, Navigation, or Static Guides

Junyu Shi, Maurizio S. Tonetti, Xiao‐Yuan Wu, Xiaolei Lv et al.
22 citations
Journal of Dental Research
Dental Implant Techniques and Outcomes
10.86
article

Comparison of Implant Precision with Robots, Navigation, or Static Guides

Junyu Shi, Maurizio S. Tonetti, Xiao‐Yuan Wu, Xiaolei Lv, Binlei Liu, Xiaojin Fu, Hsueh‐Chou Lai, Ming Liu
article en
22 citations

Abstract

Precise surgical positioning according to a digital plan is important for aesthetic and biologically stable dental implant restorations. This randomized controlled trial compared implant placement assisted by robotic surgery (RS), dynamic navigation (DN), or 3-dimensional printed static guide (SG). An overall 45 patients with a missing tooth in the premolar/molar region were randomly assigned to 1 of the 3 groups. Implant positional accuracy (primary outcome), early wound healing, soft tissue microcirculation, patient-reported outcome measures, and surgeon preference were measured by calibrated blind examiners. One adverse event occurred in DN and RS. In RS (<i>n</i> = 15), the global platform, apex deviation, and angular deviations (mean ± SD) were 1.1 ± 0.4 mm, 1.5 ± 0.6 mm, and 4.7° ± 2.5°, respectively. Similarly, deviations were 1.3 ± 0.6 mm, 1.9 ± 0.9 mm, and 5.5° ± 3.5° in the DN group (<i>n</i> = 14) and 1.1 ± 0.6 mm, 2.0 ± 1.2 mm, and 6.2° ± 4.0° in the SG group (<i>n</i> = 13). Significantly smaller differential deviations (mesial-distal) at the platform and apex levels were found in the RS group than the SG group (<i>P</i> < 0.05). Surgery was significantly shorter with a SG (<i>P</i> < 0.001), and this was associated with better postoperative recovery at 3 d. The surgeon assessed DN as providing easier access to reach the surgical site. No significant differences were found upon comparing soft tissue microcirculation and oxygen saturation immediately, 1 h, or 7 d after surgery. Patient-reported outcomes were comparable in the 3 groups, except that patients in the SG group reported better oral health-related quality of life 3 d after surgery. It can be concluded that RS showed near-zero 3-dimensional systematic error in implant position, while DN and SG demonstrated a centrifugal error pattern. All 3 guided approaches had uneventful wound healing and acceptable patient-reported outcomes. The 3 groups had specific cost-benefit profiles. After additional technical developments, future trials with larger sample sizes and longer follow-up periods should be performed to analyze the cost-effectiveness of different guided surgical approaches.

Journal of Dental ResearchVol. 104(1)
Shanghai Jiao Tong University (CN), National Clinical Research Center for Digestive Diseases (CN), Shanghai Ninth People's Hospital (CN)
Openalex Percentile: Top 1%
Dental Implant Techniques and Outcomes
10.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.