Impact of radiation dose and iterative reconstruction (IR) level on low-contrast detectability with 4-AFC approach

This study evaluated impacts of dose and iterative reconstruction (IR) level on low-contrast detectability in images of AAPM CT Performance phantom using a 4-alternative forced choice (4-AFC) approach. Five medical physicists detected low-contrast and small objects having size of 3.0 mm with the 4-AFC method. The tests were conducted at three different radiation doses (35.8 mGy, 54.1 mGy, and 72.1 mGy) at various IR levels from 0% to 100%. The total number of 4-AFC questions was 330 questions in which each observer answered the questions in 60 minutes. Percent correct answers increase as the IR level increases from 0 to 100%. The percent correct answers also increase as the dose increases from 34.8 mGy to 72.1 mGy. 100% correct answers start at IR levels of 70, 60, and 40% for doses of 34.8, 54.1, and 72.1 mGy, respectively. Conclusions: Increasing IR level and dose improve image quality, i.e., higher average percent correct answers. At IR levels around 50%, the average percent correct is close to the maximum (around 100%) for all radiation doses. An optimal combination of IR and radiation dose can produce good image quality with lower radiation dose.

Authors

Institutions

Publication Details

Journal
International Journal of Scientific Research in Science and Technology
Published
2024-11-25
DOI
https://doi.org/10.32628/ijsrst24116181
Citations
2
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of radiation dose and iterative reconstruction (IR) level on low-contrast detectability with 4-AFC approach

Heri Sutanto, Ariij Naufal, Choirul Anam, Riska Amilia et al.
2 citations
International Journal of Scientific Research in Science and Technology
Radiation Dose and Imaging
0.81
article

Impact of radiation dose and iterative reconstruction (IR) level on low-contrast detectability with 4-AFC approach

Heri Sutanto, Ariij Naufal, Choirul Anam, Riska Amilia, Indah R. Ilham
article en
2 citations

Abstract

This study evaluated impacts of dose and iterative reconstruction (IR) level on low-contrast detectability in images of AAPM CT Performance phantom using a 4-alternative forced choice (4-AFC) approach. Five medical physicists detected low-contrast and small objects having size of 3.0 mm with the 4-AFC method. The tests were conducted at three different radiation doses (35.8 mGy, 54.1 mGy, and 72.1 mGy) at various IR levels from 0% to 100%. The total number of 4-AFC questions was 330 questions in which each observer answered the questions in 60 minutes. Percent correct answers increase as the IR level increases from 0 to 100%. The percent correct answers also increase as the dose increases from 34.8 mGy to 72.1 mGy. 100% correct answers start at IR levels of 70, 60, and 40% for doses of 34.8, 54.1, and 72.1 mGy, respectively. Conclusions: Increasing IR level and dose improve image quality, i.e., higher average percent correct answers. At IR levels around 50%, the average percent correct is close to the maximum (around 100%) for all radiation doses. An optimal combination of IR and radiation dose can produce good image quality with lower radiation dose.

International Journal of Scientific Research in Science and TechnologyVol. 11(6)
Diponegoro University (ID)
Openalex Percentile: Top 24%
Radiation Dose and Imaging
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.