Vacuum frequency measurement of <sup>7</sup>S<sub>3</sub>-<sup>7</sup>P<sub>4</sub> transition in Cr atoms using laser-induced fluorescence

Abstract The nanometric length traceability chain is the foundation of cutting-edge research at the nanoscale. The current traceability chain has limitations in its applications. However, the application performance of the nanometric traceability chain based on the 7 S 3 - 7 P 4 transition in chromium atoms has been fully validated. Addressing the issue that the 7 S 3 - 7 P 4 transition frequency at the traceability side of this chain has not been measured in a vacuum environment, this study used the fluorescence symmetry method under vacuum conditions to measure the 7 S 3 - 7 P 4 transition frequency, obtaining the corresponding vacuum wavelength of 425.5533474 nm and the vacuum wave number of 23498.81645 cm −1 .

Authors

Institutions

Publication Details

Journal
Applied Physics Express
Published
2024-11-25
DOI
https://doi.org/10.35848/1882-0786/ad9702
Citations
6
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
1.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vacuum frequency measurement of 7S3-7P4 transition in Cr atoms using laser-induced fluorescence

Deng Xiao, Jianbo Wang, Guangxu Xiao, Ming Kong et al.
6 citations
Applied Physics Express
Spectroscopy and Laser Applications
1.44
article

Vacuum frequency measurement of 7S3-7P4 transition in Cr atoms using laser-induced fluorescence

Deng Xiao, Jianbo Wang, Guangxu Xiao, Ming Kong, Tong Zhou, Xinbin Cheng, Tongbao Li, Cong Yin, Lei Sun, Zhijun Yin, Yuying Xie, Jing Yu, Dongbai Xue, Junyu Shen, Feitong Ren
article en
6 citations

Abstract

Abstract The nanometric length traceability chain is the foundation of cutting-edge research at the nanoscale. The current traceability chain has limitations in its applications. However, the application performance of the nanometric traceability chain based on the 7 S 3 - 7 P 4 transition in chromium atoms has been fully validated. Addressing the issue that the 7 S 3 - 7 P 4 transition frequency at the traceability side of this chain has not been measured in a vacuum environment, this study used the fluorescence symmetry method under vacuum conditions to measure the 7 S 3 - 7 P 4 transition frequency, obtaining the corresponding vacuum wavelength of 425.5533474 nm and the vacuum wave number of 23498.81645 cm −1 .

Applied Physics ExpressVol. 17(12)
Tongji University (CN), National Institute of Metrology (CN), China Jiliang University (CN)
National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Major Projects of Special Development Funds in Zhangjiang National Independent Innovation Demonstration Zone, Shanghai, National Key Research and Development Program of China
Openalex Percentile: Top 19%
Spectroscopy and Laser Applications
1.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.