Enhancing the porosity of biphasic calcium phosphate using polyethylene glycol as the porogen for bone regeneration applications

Biphasic calcium phosphate (BCP) has been used as a material to support bone grafting, repair, recovery, and regeneration over the past decades. However, the inherent weakness of BCP is its low porosity, which limits the infiltration, differentiation, and proliferation of bone cells. To address this issue, porous BCP was synthesized using polyethylene glycol (PEG) 1000 with weight ratio ranging from 20%-60% in BCP as the porogen through the powder-forming method. Analytical methods such as Fourier transform infrared spectroscopy, x-ray diffraction, scanning electron microscopy were used to demonstrate the purity, morphology and functional groups on the material surface of the obtained BCP samples. Structurally, the BCP sample with 60% PEG, named B60, possessed the highest porosity of 71% and its pore diameters ranging from 5 to 75 µm. Besides, the<i>in vitro</i>biocompatibility of B60 material have been demonstrated on the L929 cell line (90% cell viability) and simulated body fluid (apatite formation after 1 d). These results suggested that B60 should be further studied as a promising artificial material for bone regenerating applications.

Authors

Institutions

Publication Details

Journal
Biomedical Materials
Published
2024-11-25
DOI
https://doi.org/10.1088/1748-605x/ad971f
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the porosity of biphasic calcium phosphate using polyethylene glycol as the porogen for bone regeneration applications

Ngoc Thuy Trang Le, Dai Hai Nguyen, Thanh Son Cu, Ngoc Hoi Nguyen et al.
1 citations
Biomedical Materials
Bone Tissue Engineering Materials
0.18
article

Enhancing the porosity of biphasic calcium phosphate using polyethylene glycol as the porogen for bone regeneration applications

Ngoc Thuy Trang Le, Dai Hai Nguyen, Thanh Son Cu, Ngoc Hoi Nguyen, Anh Phuong Nguyen Hong, Thị Thanh Thủy Nguyễn, Yen Pham, Luan Minh Nguyen, Thi Phuong Le, Quoc Vinh Ho
article en
1 citations

Abstract

Biphasic calcium phosphate (BCP) has been used as a material to support bone grafting, repair, recovery, and regeneration over the past decades. However, the inherent weakness of BCP is its low porosity, which limits the infiltration, differentiation, and proliferation of bone cells. To address this issue, porous BCP was synthesized using polyethylene glycol (PEG) 1000 with weight ratio ranging from 20%-60% in BCP as the porogen through the powder-forming method. Analytical methods such as Fourier transform infrared spectroscopy, x-ray diffraction, scanning electron microscopy were used to demonstrate the purity, morphology and functional groups on the material surface of the obtained BCP samples. Structurally, the BCP sample with 60% PEG, named B60, possessed the highest porosity of 71% and its pore diameters ranging from 5 to 75 µm. Besides, the<i>in vitro</i>biocompatibility of B60 material have been demonstrated on the L929 cell line (90% cell viability) and simulated body fluid (apatite formation after 1 d). These results suggested that B60 should be further studied as a promising artificial material for bone regenerating applications.

Biomedical MaterialsVol. 20(1)
Vietnam Academy of Science and Technology (VN)
Clean water and sanitation
Openalex Percentile: Top 50%
Bone Tissue Engineering Materials
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.