A positionally stable anatomic smooth breast implant

The voluntary recall of textured breast implants due to their association with breast implant-associated anaplastic large cell lymphoma has resulted in the loss of the primary advantage of the textured surface: positional stability. We have engineered a novel soft gel-filled smooth implant with a surface that promotes positional stability without texture, known as the positionally stable smooth implant (PSSI). Miniature anatomically shaped breast implant shells were fabricated from polydimethylsiloxane using 3D-printed molds. The implant shell design incorporates cylindrical wells 1-4 mm in diameter. Implants were filled with commercial breast implant-derived silicone gel. Smooth and textured implants were also fabricated, serving as controls. Six implants per group were implanted subcutaneously into the bilateral rat dorsum. Rotation was measured every 2 weeks for a total of 12 weeks to assess stability. Animals were sacrificed at 4 and 12 weeks, and implant-capsule units were explanted for histological and Micro-computed tomography (MicroCT) analyzes. Four weeks after implantation, PSSI conditions showed tissue ingrowth and conformation to well dimensions, as assessed by histological staining and MicroCT imaging. Twelve weeks post implantation, textured implants and PSSI conditions with larger widths, depths, and well number demonstrated statistically significant increased stability compared to smooth implants (<i>p</i>< 0.05). Tissue ingrowth into shell features occurred by 4 weeks and remained throughout longer time points. No significant differences were found in capsule thickness or collagen content between groups. These results suggest a promising alternative to textured surfaces for inducing implant positional stability.

Authors

Institutions

Publication Details

Journal
Biomedical Materials
Published
2024-11-25
DOI
https://doi.org/10.1088/1748-605x/ad9721
Citations
2
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A positionally stable anatomic smooth breast implant

George S. Corpuz, Gillian O’Connell, Hector F. Salazar, Jason A. Spector et al.
2 citations
Biomedical Materials
Breast Implant and Reconstruction
1.15
article

A positionally stable anatomic smooth breast implant

George S. Corpuz, Gillian O’Connell, Hector F. Salazar, Jason A. Spector, Sophia Salingaros, Lawrence Bonassar, Luke Poveromo, Celia Aboaf, Tim Li, Xue Dong, Carlos Y Urrea De La Puerta
article en
2 citations

Abstract

The voluntary recall of textured breast implants due to their association with breast implant-associated anaplastic large cell lymphoma has resulted in the loss of the primary advantage of the textured surface: positional stability. We have engineered a novel soft gel-filled smooth implant with a surface that promotes positional stability without texture, known as the positionally stable smooth implant (PSSI). Miniature anatomically shaped breast implant shells were fabricated from polydimethylsiloxane using 3D-printed molds. The implant shell design incorporates cylindrical wells 1-4 mm in diameter. Implants were filled with commercial breast implant-derived silicone gel. Smooth and textured implants were also fabricated, serving as controls. Six implants per group were implanted subcutaneously into the bilateral rat dorsum. Rotation was measured every 2 weeks for a total of 12 weeks to assess stability. Animals were sacrificed at 4 and 12 weeks, and implant-capsule units were explanted for histological and Micro-computed tomography (MicroCT) analyzes. Four weeks after implantation, PSSI conditions showed tissue ingrowth and conformation to well dimensions, as assessed by histological staining and MicroCT imaging. Twelve weeks post implantation, textured implants and PSSI conditions with larger widths, depths, and well number demonstrated statistically significant increased stability compared to smooth implants (<i>p</i>< 0.05). Tissue ingrowth into shell features occurred by 4 weeks and remained throughout longer time points. No significant differences were found in capsule thickness or collagen content between groups. These results suggest a promising alternative to textured surfaces for inducing implant positional stability.

Biomedical MaterialsVol. 20(1)
Cornell University (US)
Openalex Percentile: Top 19%
Breast Implant and Reconstruction
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.