NIM diffuse reflectance scale to super black level (0.0001)

Abstract The realization of the super black level diffuse reflectance scale of the National Institute of Metrology (NIM, China) is presented. Two facilities were used to achieve the reflectance scale under 0 d condition covering 0.0001–1.0 (absolute value), the first one based on the supercontinuum light source was used to realize the diffuse scale in the wavelength range 500 nm–2000 nm, while the other one based on QCL was applied for the mid infrared range from 7.5 μm to 10.6 μm. The relative expanded uncertainty ( k = 2) of the reflectance scale was evaluated to be from 2.3% to 8.4% varying with range and wavelength in visible band to near infrared band while the reflectance is down to 0.0001. In the mid infrared band, the uncertainty of the reflectance scale was up to 8.9% while reflectance is 0.001, and up to 42.6% while reflectance is down to 0.0001. This low reflectance level scale can meet the calibration requirement of super black material or system such as carbon nanotube or blackbody.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2024-11-25
DOI
https://doi.org/10.1088/1681-7575/ad96c0
Primary Topic
Optical Coatings and Gratings
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NIM diffuse reflectance scale to super black level (0.0001)

Guojin Feng, Yingwei He, Qiaoxiang Zhang, Yandong Lin et al.
Metrologia
Optical Coatings and Gratings
article

NIM diffuse reflectance scale to super black level (0.0001)

Guojin Feng, Yingwei He, Qiaoxiang Zhang, Yandong Lin, Chundi Zheng, Yuxuan Ma, Ruoduan Sun, Haiyong Gan, Houping Wu
article en

Abstract

Abstract The realization of the super black level diffuse reflectance scale of the National Institute of Metrology (NIM, China) is presented. Two facilities were used to achieve the reflectance scale under 0 d condition covering 0.0001–1.0 (absolute value), the first one based on the supercontinuum light source was used to realize the diffuse scale in the wavelength range 500 nm–2000 nm, while the other one based on QCL was applied for the mid infrared range from 7.5 μm to 10.6 μm. The relative expanded uncertainty ( k = 2) of the reflectance scale was evaluated to be from 2.3% to 8.4% varying with range and wavelength in visible band to near infrared band while the reflectance is down to 0.0001. In the mid infrared band, the uncertainty of the reflectance scale was up to 8.9% while reflectance is 0.001, and up to 42.6% while reflectance is down to 0.0001. This low reflectance level scale can meet the calibration requirement of super black material or system such as carbon nanotube or blackbody.

MetrologiaVol. 62(1)
China Electronics Technology Group Corporation (CN), National Institute of Metrology (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 80%
Optical Coatings and Gratings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

NIM diffuse reflectance scale to super black level (0.0001) — Guojin Feng, Yingwei He, et al. · Metrologia (2024) | TGRS Research Map | TGRS