Elimination of hand-induced parasitic vibration in self-mixing displacement measurement based on FFT

A method of removing hand-induced parasitic vibration is presented based on FFT for a handheld self-mixing (SM) displacement sensor measuring mechanical vibration. Parasitic vibration has been measured by and large with solid-state accelerometers (SSAs) and, in doing so, removed. Such methods increase the complexity of the device and the cost since they need additional hardware and a complicated algorithm for elimination of parasitic vibration. The proposed method can be applied to all cases where the frequency of a measurement object is different by only a few hertz from the main frequency of the parasitic vibration as well as the case of hand-induced parasitic vibration. The error of displacement retrieval of the method was found to be less than 30 nm. This method will be a great help to the development of handheld portable SM displacement sensors.

Authors

Publication Details

Journal
Applied Optics
Published
2024-11-25
DOI
https://doi.org/10.1364/ao.540087
Citations
2
Primary Topic
Semiconductor Lasers and Optical Devices
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elimination of hand-induced parasitic vibration in self-mixing displacement measurement based on FFT

Myong-Il Kim, Hyok-Chol Kim, Won-Song Ju, Hui-Sung Hong et al.
2 citations
Applied Optics
Semiconductor Lasers and Optical Devices
0.42
article

Elimination of hand-induced parasitic vibration in self-mixing displacement measurement based on FFT

Myong-Il Kim, Hyok-Chol Kim, Won-Song Ju, Hui-Sung Hong, Chol-Hyon Kim, Gun-Jong Ko
article en
2 citations

Abstract

A method of removing hand-induced parasitic vibration is presented based on FFT for a handheld self-mixing (SM) displacement sensor measuring mechanical vibration. Parasitic vibration has been measured by and large with solid-state accelerometers (SSAs) and, in doing so, removed. Such methods increase the complexity of the device and the cost since they need additional hardware and a complicated algorithm for elimination of parasitic vibration. The proposed method can be applied to all cases where the frequency of a measurement object is different by only a few hertz from the main frequency of the parasitic vibration as well as the case of hand-induced parasitic vibration. The error of displacement retrieval of the method was found to be less than 30 nm. This method will be a great help to the development of handheld portable SM displacement sensors.

Applied OpticsVol. 63(36)
Openalex Percentile: Top 36%
Semiconductor Lasers and Optical Devices
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Elimination of hand-induced parasitic vibration in self-mixing displacement measurement based on FFT — Myong-Il Kim, Hyok-Chol Kim, et al. · Applied Optics (2024) | TGRS Research Map | TGRS