Lyophilized T Cell Reference Materials with Quantified Proportions of Subtypes

The accurate quantification of T cell subtypes and their proportions is of great significance in cell-based biomanufacturing, diagnosis, and advanced therapy. The development and application of a cell reference material (RM) provide a solid foundation for reliable and consistent T cell quantification worldwide. However, creating a cell RM that is both accurate and practical remains a challenge. In this study, we have developed a series of T cell RMs with a certified subtype proportion based on traceable accurate quantification and stable long-term preservation. We developed a quantitative flow cytometry method for the ratio of T cell subtypes with improved accuracy by using the calibration of certified reference materials of polystyrene beads. The relative standard deviation (RSD) for the quantification of CD3<sup>+</sup>, CD4<sup>+</sup>, and CD8<sup>+</sup> subtypes was 0.43%, 0.64%, and 1.31%, respectively. To ensure long-term stability, an innovative lyophilization preservation technique was developed for our T cell RMs. The morphology and surface antigens (CD45, CD3, CD4, and CD8) of T cell RMs were characterized after lyophilization using immunofluorescence, demonstrating their equally good integrity compared with fresh cells. Their stability at 4 °C was demonstrated by continuous monitoring over 12 months. The final value assignment of the RMs was performed through quantification using flow cytometry in different laboratories. One of our RMs has been applied for the calibration of 54 different flow cytometry instruments. The T cell RMs have outstanding potential in the quality control of multiparameter flow cytometry measurements, and we believe they have great application prospects for the establishment and validation of T cell assays.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2024-11-25
DOI
https://doi.org/10.1021/acsomega.4c06867
Primary Topic
Single-cell and spatial transcriptomics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lyophilized T Cell Reference Materials with Quantified Proportions of Subtypes

Min Ding, Yinbo Huo, Wen‐Tzong Liang, Juan Yan et al.
ACS Omega
Single-cell and spatial transcriptomics
article

Lyophilized T Cell Reference Materials with Quantified Proportions of Subtypes

Min Ding, Yinbo Huo, Wen‐Tzong Liang, Juan Yan, Hui Xu, Lanying Li, Feiyan Gong, Jiaqi Yang, Gang Liu, Yan Li, Li Xu, Yanli Wen, Qing Tao
article en

Abstract

The accurate quantification of T cell subtypes and their proportions is of great significance in cell-based biomanufacturing, diagnosis, and advanced therapy. The development and application of a cell reference material (RM) provide a solid foundation for reliable and consistent T cell quantification worldwide. However, creating a cell RM that is both accurate and practical remains a challenge. In this study, we have developed a series of T cell RMs with a certified subtype proportion based on traceable accurate quantification and stable long-term preservation. We developed a quantitative flow cytometry method for the ratio of T cell subtypes with improved accuracy by using the calibration of certified reference materials of polystyrene beads. The relative standard deviation (RSD) for the quantification of CD3<sup>+</sup>, CD4<sup>+</sup>, and CD8<sup>+</sup> subtypes was 0.43%, 0.64%, and 1.31%, respectively. To ensure long-term stability, an innovative lyophilization preservation technique was developed for our T cell RMs. The morphology and surface antigens (CD45, CD3, CD4, and CD8) of T cell RMs were characterized after lyophilization using immunofluorescence, demonstrating their equally good integrity compared with fresh cells. Their stability at 4 °C was demonstrated by continuous monitoring over 12 months. The final value assignment of the RMs was performed through quantification using flow cytometry in different laboratories. One of our RMs has been applied for the calibration of 54 different flow cytometry instruments. The T cell RMs have outstanding potential in the quality control of multiparameter flow cytometry measurements, and we believe they have great application prospects for the establishment and validation of T cell assays.

ACS OmegaVol. 9(49)
Huzhou Normal University (CN), Shanghai Institute of Measurement and Testing Technology (CN), Shanghai Ocean University (CN)
National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Shanghai Ocean University
Climate action
Openalex Percentile: Top 81%
Single-cell and spatial transcriptomics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.