Evaporation Peculiarities of Soft Biological Tissues in the Process of Automated 2D-Scanning of CO2 Laser Radiation

The peculiarities of laser evaporation of soft biological tissues in the process of two-dimensional scanning of continuous CO 2 laser radiation were studied experimentally and numerically. Samples from agar and pig heart muscle in vitro were used as soft biotissue models. The depth of evaporation and the peculiarities of the formed surface of the evaporated zone were studied for different regimes of exposure: radiation power, scanning speed of the laser beam, filling density of the scanned zone. A semi-empirical model of laser evaporation of soft biological tissues with high water content is proposed based on the energy balance and the evaporative mechanism of biotissue removal. Studies have shown good agreement between experimental data and data obtained based on the proposed model.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Photonics & Engineering
Published
2024-11-10
DOI
https://doi.org/10.18287/jbpe24.10.040307
Citations
1
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaporation Peculiarities of Soft Biological Tissues in the Process of Automated 2D-Scanning of CO2 Laser Radiation

А. К. Дмитриев, V. N. Kortunov, Valery A. Ul'yanov, А. Н. Коновалов
1 citations
Journal of Biomedical Photonics & Engineering
Laser Applications in Dentistry and Medicine
0.40
article

Evaporation Peculiarities of Soft Biological Tissues in the Process of Automated 2D-Scanning of CO2 Laser Radiation

А. К. Дмитриев, V. N. Kortunov, Valery A. Ul'yanov, А. Н. Коновалов
article en
1 citations

Abstract

The peculiarities of laser evaporation of soft biological tissues in the process of two-dimensional scanning of continuous CO 2 laser radiation were studied experimentally and numerically. Samples from agar and pig heart muscle in vitro were used as soft biotissue models. The depth of evaporation and the peculiarities of the formed surface of the evaporated zone were studied for different regimes of exposure: radiation power, scanning speed of the laser beam, filling density of the scanned zone. A semi-empirical model of laser evaporation of soft biological tissues with high water content is proposed based on the energy balance and the evaporative mechanism of biotissue removal. Studies have shown good agreement between experimental data and data obtained based on the proposed model.

Journal of Biomedical Photonics & EngineeringVol. 10(4)
Kurchatov Institute (RU)
Openalex Percentile: Top 32%
Laser Applications in Dentistry and Medicine
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.