Performance of optically pumped magnetometer magnetoencephalography: validation in large samples and multiple tasks

<i>Objective.</i>Current commercial magnetoencephalography (MEG) systems detect neuro-magnetic signals using superconducting quantum interference devices (SQUIDs), which require liquid helium as cryogen and have many limitations during operation. In contrast, optically pumped magnetometers (OPMs) technology provides a promising alternative to conventional SQUID-MEG. OPMs can operate at room temperature, offering benefits such as flexible deployment and lower costs. However, the validation of OPM-MEG has primarily been conducted on small sample sizes and specific regions of interest in the brain, lacking comprehensive validation for larger sample sizes and assessment of whole-brain.<i>Approach.</i>We recruited 100 participants, including healthy and neurological disorders individuals. Whole-brain OPM-MEG and SQUID-MEG data were recorded sequentially during auditory (<i>n</i>= 50) and visual (<i>n</i>= 50) stimulation experiments. By comparing the task-evoked responses of the two systems, we aimed to validate the performance of the next-generation OPM-MEG.<i>Main results.</i>The results showed that OPM-MEG enhanced the amplitude of task-related responses and exhibited similar magnetic field patterns and neural oscillatory activity as SQUID-MEG. There was no difference in the task-related latencies measured by the two systems. The signal-to-noise ratio was lower for the OPM-MEG in the auditory experiment, but did not differ in the visual experiment, suggesting that the results may be task-dependent.<i>Significance.</i>These results demonstrate that OPM-MEG, as an alternative to traditional SQUID-MEG, shows superior response amplitude and comparable performance in capturing brain dynamics. This study provides evidence for the effectiveness of OPM-MEG as a next-generation neuroimaging technique.

Authors

Institutions

Publication Details

Journal
Journal of Neural Engineering
Published
2024-11-24
DOI
https://doi.org/10.1088/1741-2552/ad9680
Citations
6
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
2.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of optically pumped magnetometer magnetoencephalography: validation in large samples and multiple tasks

Jia‐Hong Gao, Guoming Luan, Xiongfei Wang, Jingwei Sheng et al.
6 citations
Journal of Neural Engineering
Atomic and Subatomic Physics Research
2.03
article

Performance of optically pumped magnetometer magnetoencephalography: validation in large samples and multiple tasks

Jia‐Hong Gao, Guoming Luan, Xiongfei Wang, Jingwei Sheng, Mengyang Wang, Qiujian Meng, Jiangfen Wu, Yuguang Guan, Tianfu Li, Jian Zhou, Yuying Jiang, Pengfei Teng
article en
6 citations

Abstract

<i>Objective.</i>Current commercial magnetoencephalography (MEG) systems detect neuro-magnetic signals using superconducting quantum interference devices (SQUIDs), which require liquid helium as cryogen and have many limitations during operation. In contrast, optically pumped magnetometers (OPMs) technology provides a promising alternative to conventional SQUID-MEG. OPMs can operate at room temperature, offering benefits such as flexible deployment and lower costs. However, the validation of OPM-MEG has primarily been conducted on small sample sizes and specific regions of interest in the brain, lacking comprehensive validation for larger sample sizes and assessment of whole-brain.<i>Approach.</i>We recruited 100 participants, including healthy and neurological disorders individuals. Whole-brain OPM-MEG and SQUID-MEG data were recorded sequentially during auditory (<i>n</i>= 50) and visual (<i>n</i>= 50) stimulation experiments. By comparing the task-evoked responses of the two systems, we aimed to validate the performance of the next-generation OPM-MEG.<i>Main results.</i>The results showed that OPM-MEG enhanced the amplitude of task-related responses and exhibited similar magnetic field patterns and neural oscillatory activity as SQUID-MEG. There was no difference in the task-related latencies measured by the two systems. The signal-to-noise ratio was lower for the OPM-MEG in the auditory experiment, but did not differ in the visual experiment, suggesting that the results may be task-dependent.<i>Significance.</i>These results demonstrate that OPM-MEG, as an alternative to traditional SQUID-MEG, shows superior response amplitude and comparable performance in capturing brain dynamics. This study provides evidence for the effectiveness of OPM-MEG as a next-generation neuroimaging technique.

Journal of Neural EngineeringVol. 21(6)
General Electric (Spain) (ES), Peking University (CN), Beijing Sanbo Brain Hospital (CN), Jingdong (China) (CN), Chinese Institute for Brain Research (CN)
Beijing Nova Program
Openalex Percentile: Top 13%
Atomic and Subatomic Physics Research
2.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.