Evaluating the accuracy of an automatic counting system to detect dispensing of hand hygiene product
The MEZRIT™ system accurately identified 90 % of HH events and excluded 100 % of non-HH events. The real-time monitoring of HH product usage may be beneficial in responding quickly to changes in product usage.
Authors
- Philip L. Russo (ORCID: https://orcid.org/0000-0003-3822-0554)
- Katrina Browne (ORCID: https://orcid.org/0000-0001-8141-0092)
- BRETT G. MITCHELL (ORCID: https://orcid.org/0000-0003-4220-8291)
- Sonja Dawson (ORCID: https://orcid.org/0000-0002-9145-212X)
- Georgia Matterson (ORCID: https://orcid.org/0009-0009-2483-5938)
- Hannah Kent
Institutions
- Avondale University (AU)
- Gosford Hospital (AU)
- Cabrini Hospital (AU)
Publication Details
- Journal
- Infection Disease & Health
- Published
- 2024-11-23
- DOI
- https://doi.org/10.1016/j.idh.2024.11.001
- Citations
- 2
- Primary Topic
- Food Safety and Hygiene
- Type
- article
- Field-Weighted Citation Impact
- 0.70