Soft fault detection strategies in heat pumps: A case study investigating virtual sensor methodologies for evaporator fouling

Heat pumps, known for their energy efficiency, can experience soft faults, such as evaporator fouling, that degrade performance while allowing continued operation, making detection challenging. This study presents a method for detecting evaporator fouling in air-to-water heat pumps using virtual sensors. These sensors estimate key parameters, including condensing and evaporating temperatures, refrigerant mass flow rate, and air enthalpy at the evaporator outlet. The approach relies only on variables typically measured in the system – such as those from the compressor, fan control, and secondary fluids (air and water) – eliminating the need for direct refrigerant measurements. Virtual sensors are calibrated against simulated fault-free performance maps and tested on a heat pump with variable-speed components. The method’s effectiveness is assessed through simulations and experiments with induced evaporator fouling. Simulations show high accuracy, with deviations within ± 5%; however, experimental results exhibit higher deviations due to challenges in measuring air dry-bulb temperature at the evaporator outlet, where fouling leads to non-uniform airflow. Despite these limitations, virtual sensors offer a cost-effective and practical alternative to traditional physical sensors for fault detection.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-11-23
DOI
https://doi.org/10.1016/j.csite.2024.105508
Citations
4
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Soft fault detection strategies in heat pumps: A case study investigating virtual sensor methodologies for evaporator fouling

Belén Llopis-Mengual, Emilio Navarro-Peris, Javier Marchante-Avellaneda
4 citations
Case Studies in Thermal Engineering
Refrigeration and Air Conditioning Technologies
0.85
article

Soft fault detection strategies in heat pumps: A case study investigating virtual sensor methodologies for evaporator fouling

Belén Llopis-Mengual, Emilio Navarro-Peris, Javier Marchante-Avellaneda
article en
4 citations

Abstract

Heat pumps, known for their energy efficiency, can experience soft faults, such as evaporator fouling, that degrade performance while allowing continued operation, making detection challenging. This study presents a method for detecting evaporator fouling in air-to-water heat pumps using virtual sensors. These sensors estimate key parameters, including condensing and evaporating temperatures, refrigerant mass flow rate, and air enthalpy at the evaporator outlet. The approach relies only on variables typically measured in the system – such as those from the compressor, fan control, and secondary fluids (air and water) – eliminating the need for direct refrigerant measurements. Virtual sensors are calibrated against simulated fault-free performance maps and tested on a heat pump with variable-speed components. The method’s effectiveness is assessed through simulations and experiments with induced evaporator fouling. Simulations show high accuracy, with deviations within ± 5%; however, experimental results exhibit higher deviations due to challenges in measuring air dry-bulb temperature at the evaporator outlet, where fouling leads to non-uniform airflow. Despite these limitations, virtual sensors offer a cost-effective and practical alternative to traditional physical sensors for fault detection.

Case Studies in Thermal EngineeringVol. 64
Universitat Politècnica de València (ES)
Affordable and clean energy, Climate action
Openalex Percentile: Top 30%
Refrigeration and Air Conditioning Technologies
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Soft fault detection strategies in heat pumps: A case study investigating virtual sensor methodologies for evaporator fouling — Belén Llopis-Mengual, Emilio Navarro-Peris, et al. · Case Studies in Thermal Engineering (2024) | TGRS Research Map | TGRS