Self‐Extracting Dextran‐Based Hydrogel Microneedle Arrays with an Interpenetrating Bioelectroenzymatic Sensor for Transdermal Monitoring with Matrix Protection

Continuous glucose monitors have revolutionized diabetes management, yet such devices are limited by their cost, invasiveness, and stability. Microneedle (MN) arrays could offer improved comfort compared to invasive implanted or mm-sized needle devices, but such arrays are hampered by complex fabrication processes, limited mechanical and sensor stability, and/or cytotoxicity concerns. This work demonstrates the first crosslinked hydrogel microneedle-bioelectroenzymatic sensor arrays capable of biomarker extraction and robust transdermal continuous monitoring in artificial interstitial fluid for 10 days. The fabrication process via micromolding of dextran-methacrylate (Dex-MA) and dry-state visible light crosslinking is simple and permits the robust fixation of diverse prefabricated electrodes in a single array. Dry-state crosslinking minimized material shrinkage to enable the formation of resistant Dex-MA microneedles with shape control and reproducibility. The polymer substitution level (9-62%) and mass content (10-30 wt%) affect the mechanical, swelling, and bioelectrocatalytic properties of the integrated sensors. Crosslinked Dex-MA hydrogel matrices provide beneficial cytotoxicity protection and flux-limiting membrane properties to the integrated second generation dehydrogenase-based nanostructured buckypaper biosensor and Ag/AgCl reference electrodes. Polysaccharide-based microneedle technology with encapsulated porous bioelectrodes promise to be a valuable alternative to more invasive devices for safer and longer-term biomarker monitoring.

Authors

Institutions

Publication Details

Journal
Advanced Healthcare Materials
Published
2024-11-24
DOI
https://doi.org/10.1002/adhm.202403209
Citations
16
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
3.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self‐Extracting Dextran‐Based Hydrogel Microneedle Arrays with an Interpenetrating Bioelectroenzymatic Sensor for Transdermal Monitoring with Matrix Protection

Marta Sacchi, Andrew J. Gross, Isabelle Texier, Bastien Darmau
16 citations
Advanced Healthcare Materials
Electrochemical sensors and biosensors
3.34
article

Self‐Extracting Dextran‐Based Hydrogel Microneedle Arrays with an Interpenetrating Bioelectroenzymatic Sensor for Transdermal Monitoring with Matrix Protection

Marta Sacchi, Andrew J. Gross, Isabelle Texier, Bastien Darmau
article en
16 citations

Abstract

Continuous glucose monitors have revolutionized diabetes management, yet such devices are limited by their cost, invasiveness, and stability. Microneedle (MN) arrays could offer improved comfort compared to invasive implanted or mm-sized needle devices, but such arrays are hampered by complex fabrication processes, limited mechanical and sensor stability, and/or cytotoxicity concerns. This work demonstrates the first crosslinked hydrogel microneedle-bioelectroenzymatic sensor arrays capable of biomarker extraction and robust transdermal continuous monitoring in artificial interstitial fluid for 10 days. The fabrication process via micromolding of dextran-methacrylate (Dex-MA) and dry-state visible light crosslinking is simple and permits the robust fixation of diverse prefabricated electrodes in a single array. Dry-state crosslinking minimized material shrinkage to enable the formation of resistant Dex-MA microneedles with shape control and reproducibility. The polymer substitution level (9-62%) and mass content (10-30 wt%) affect the mechanical, swelling, and bioelectrocatalytic properties of the integrated sensors. Crosslinked Dex-MA hydrogel matrices provide beneficial cytotoxicity protection and flux-limiting membrane properties to the integrated second generation dehydrogenase-based nanostructured buckypaper biosensor and Ag/AgCl reference electrodes. Polysaccharide-based microneedle technology with encapsulated porous bioelectrodes promise to be a valuable alternative to more invasive devices for safer and longer-term biomarker monitoring.

Advanced Healthcare MaterialsVol. 14(2)
Centre National de la Recherche Scientifique (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), CEA Grenoble (FR), Direction de la Recherche Technologique (FR), Laboratoire d'Électronique des Technologies de l'Information (FR), Université Grenoble Alpes (FR)
LABoratoires d’EXcellence ARCANE, Agence Nationale de la Recherche
Openalex Percentile: Top 7%
Electrochemical sensors and biosensors
3.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.