A customized dynamic hip screw for valgus osteotomy in femoral neck nonunion with remarkable anatomy: A case report

We report the treatment of femoral neck nonunion in an adult female who has remarkable femoral neck anatomy. The initial fracture was treated by closed reduction and multiple screws incorporated pin fixation. Eventually, nonunion with implant loosening developed after about 10 following months. Therefore, trochanteric valgus osteotomy and dynamic hip screw fixation was determined to treat the nonunion. As a result of implant-anatomy mismatching, the customized lag screw was designed to compromise both of the particular anatomy and the ordinary side plate. The implant was manufactured using a Computer Numerical Control (CNC) machine. Finally, the nonunion and osteotomy site completely healed without complication.

Authors

Institutions

Publication Details

Journal
Trauma Case Reports
Published
2024-11-23
DOI
https://doi.org/10.1016/j.tcr.2024.101119
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A customized dynamic hip screw for valgus osteotomy in femoral neck nonunion with remarkable anatomy: A case report

Kongkhet Riansuwan, Posatorn Suwanpongsai
Trauma Case Reports
Hip and Femur Fractures
article

A customized dynamic hip screw for valgus osteotomy in femoral neck nonunion with remarkable anatomy: A case report

Kongkhet Riansuwan, Posatorn Suwanpongsai
article en

Abstract

We report the treatment of femoral neck nonunion in an adult female who has remarkable femoral neck anatomy. The initial fracture was treated by closed reduction and multiple screws incorporated pin fixation. Eventually, nonunion with implant loosening developed after about 10 following months. Therefore, trochanteric valgus osteotomy and dynamic hip screw fixation was determined to treat the nonunion. As a result of implant-anatomy mismatching, the customized lag screw was designed to compromise both of the particular anatomy and the ordinary side plate. The implant was manufactured using a Computer Numerical Control (CNC) machine. Finally, the nonunion and osteotomy site completely healed without complication.

Trauma Case ReportsVol. 54
Siriraj Hospital (TH), Mahidol University (TH)
Openalex Percentile: Top 60%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.